作者
Leslie Ying, Jinhua Sheng
发表日期
2007/6
期刊
Magnetic Resonance in Medicine: An Official Journal of the International Society for Magnetic Resonance in Medicine
卷号
57
期号
6
页码范围
1196-1202
出版商
Wiley Subscription Services, Inc., A Wiley Company
简介
Parallel magnetic resonance imaging (pMRI) using multichannel receiver coils has emerged as an effective tool to reduce imaging time in various applications. However, the issue of accurate estimation of coil sensitivities has not been fully addressed, which limits the level of speed enhancement achievable with the technology. The self‐calibrating (SC) technique for sensitivity extraction has been well accepted, especially for dynamic imaging, and complements the common calibration technique that uses a separate scan. However, the existing method to extract the sensitivity information from the SC data is not accurate enough when the number of data is small, and thus erroneous sensitivities affect the reconstruction quality when they are directly applied to the reconstruction equation. This paper considers this problem of error propagation in the sequential procedure of sensitivity estimation followed by image …
引用总数
200720082009201020112012201320142015201620172018201920202021202220232024187101514161831291812211925253917
学术搜索中的文章
L Ying, J Sheng - Magnetic Resonance in Medicine: An Official Journal of …, 2007