作者
Nathália Ferrare, André Ferreira Leite, Hugo César Pinto Marques Caracas, Ricardo Bentes de Azevedo, Nilce Santos de Melo, Paulo Tadeu de Souza Figueiredo
发表日期
2013/8
期刊
Surgical and Radiologic Anatomy
卷号
35
页码范围
495-502
出版商
Springer Paris
简介
Purpose
To compare cone-beam computed tomography (CBCT) and microtomography (micro-CT) for alveolar bone measurements.
Methods
Forty teeth and alveolar bone blocks of five pigs were scanned on a micro-CT with a 9.05 μm pixel size, and on a CBCT device at 0.125 mm voxel size. One height and four thickness measurements were performed twice in standardized slices by two radiologists to verify reliability. Agreement between imaging methods was assessed by correlation coefficients, Bland–Altman plots, and the difference was tested by a Wilcoxon signed-rank test.
Results
Regarding intra- and interobserver agreements, all bone measurements presented excellent precision values for micro-CT, but interobserver agreement for CBCT presented good to moderate values. Bone height differed about 0.3 mm …
引用总数
2014201520162017201820192020202120222023116283493
学术搜索中的文章
N Ferrare, AF Leite, HCPM Caracas, RB de Azevedo… - Surgical and Radiologic Anatomy, 2013