作者
Paweł Linczuk, R Krawczyk, A Wojenski, W Zabolotny, M Chernyshova, K Pozniak, T Czarski, M Gaska, G Kasprowicz, P Kolasinski, E Kowalska-Strzeciwilk, K Malinowski
发表日期
2019/5/2
期刊
Journal of Instrumentation
卷号
14
期号
05
页码范围
C05001
出版商
IOP Publishing
简介
The paper presents latency and performance study of the monitoring system for plasma impurities radiation in a tokamak. The developed solution measures radiation in Soft X-Ray range and can provide valuable information about the ongoing experiment with low latency. This work presents the test configuration with a single-dimensional pixel topology, with 64 channels, tested at photon rate about 100 kHz per channel. The hardware consists of the GEM-based detector, FPGAs, PCIe transmission system and the computer system with 64-bit x86 architecture. The software is the C/C++ code optimized for the execution time and working in the global trigger mode. The system uses raw data acquisition and the backend computations in CPU to provide high accuracy and high-quality results, not easily achievable otherwise. The research includes measurements of the throughput of the system and the latency of the …
引用总数
20192020202120223121
学术搜索中的文章