作者
Jürgen Jasperneite, Khaled Shehab, Karl Weber
发表日期
2004/9/22
研讨会论文
IEEE International Workshop on Factory Communication Systems, 2004. Proceedings.
页码范围
239-244
出版商
IEEE
简介
The IEEE-1588 standard for a high precision time synchronization now exists since 2002. For using this standard in bridged networks a so-called boundary clock is defined, where the local clock adjustment can be modeled by a corresponding control loop. At the field level of industrial automation systems, the line topology is very important. By using Ethernet at the field level, the resulting chain of bridges leads to a cascade of control loops and may lead to instabilities and deviations of the distributed clocks, which are not acceptable. For this application a bypass clock instead of the boundary clock is proposed as an enhancement of the IEEE-1588 standard. The effectiveness of this extension to be evaluated by simulation technique.
引用总数
20042005200620072008200920102011201220132014201520162017201820192020202120222023111691115116298813435215
学术搜索中的文章
J Jasperneite, K Shehab, K Weber - … Workshop on Factory Communication Systems, 2004 …, 2004