作者
N Shamsuddin, D. B Das, V. M Starov
发表日期
2015
期刊
Chemical Engineering Journal
卷号
276
页码范围
331-339
出版商
Elsevier
简介
Application of ultrafiltration membranes for removal of humic acids is investigated below. Membrane filtration processes were compared using two different set-ups: circular flow and stirred dead end flow. The transmembrane pressure, temperature, feed concentration, pH, ionic strength and shear stresses applied on the membrane surfaces were kept constant whilst the permeate flux and solute rejection were measured during the experiments with both set-ups. It was shown that the rejection (both the observed and the true rejection) in the case of circular flow was higher than in the case of dead end flow. The mass transfer coefficients were determined for both set-ups. In the case of stirred dead end, it ranged in from 2.14 to 4.72 × 10−6 m/s; however, for circular cross flow system, the mass transfer coefficients were found in the range 2.24–3.22 × 10−5 m/s. Comparison of the mass transfer coefficients obtained for …
引用总数
201520162017201820192020202120222023202441011121617121292