Results
Figure 1 (a) shows x-ray diffraction results obtained from the wires with three strains, ϵ= 0 (as-patented), ϵ= 3.6 and ϵ= 5.1. The intensity is normalized with the 011 peak from each specimen. The as-patented specimen show clear peaks corresponding to the diffractions from cementite phase. The wire with a strain of 3.6 show weak diffraction peak, suggesting that the volume fraction of cementite decreased after cold drawing. Broadening of the cementite diffraction suggests that the