Background
Kidney transplantation (KT) is the best renal replacement treatment. The rewarming time is associated with ischemia/reperfusion damage. In both the open (open KT [OKT]) and the robotic (robotic-assisted KT [RAKT]) approaches, ice slush is used to maintain graft temperature (T°) below 20 °C. This may result in nonhomogeneous graft T° maintenance and, particularly during RAKT where the graft is completely inside the abdominal cavity, rises concerns regarding systemic hypothermia.
Objective
To design a cold ischemia device (CID) to maintain a constant and homogeneous low graft T° during surgery.
Design, setting, and participants
In IDEAL phase 0, a CID was developed and tested to determine its cooling effect on the kidney inside a closed system at 37.5 °C, by comparing it with kidney alone versus a gauze-jacket filled with ice slush. The CID was evaluated in pigs undergoing OKT and RAKT …