简介
The ends of a coped beam are commonly connected to the web of a girder by double clip angles. The clip angles may either be bolted or welded to the web of the beam. One of the potential modes for the failure of the clip angle connection is the block shear of the beam web material. To investigate the strength and the behavior of the block shear of coped beams with welded end connections, ten full-scale coped beam tests were conducted. The test parameters included the aspect ratio of the clip angles, the web shear and tension area around the clip angles, the web thickness, beam section depth, cope length, and connection position. The test results indicated that the specimens failed, developing either tension fractures of the web near the bottom of the clip angles or local web buckling near the end of the cope. Although the final failure mode of the six specimens was local web buckling, it was observed during the …