作者
Rodrigo De Souza Couto, Stefano Secci, Miguel Elias Mitre Campista, Luís Henrique Maciel Kosmalski Costa
发表日期
2016/4
期刊
Journal of Network and Systems Management
卷号
24
页码范围
346-392
出版商
Springer US
简介
The architecture of several data centers have been proposed as alternatives to the conventional three-layer one. Most of them employ commodity equipment for cost reduction. Thus, robustness to failures becomes even more important, because commodity equipment is more failure-prone. Each architecture has a different network topology design with a specific level of redundancy. In this work, we aim at analyzing the benefits of different data center topologies taking the reliability and survivability requirements into account. We consider the topologies of three alternative data center architecture: Fat-tree, BCube, and DCell. Also, we compare these topologies with a conventional three-layer data center topology. Our analysis is independent of specific equipment, traffic patterns, or network protocols, for the sake of generality. We derive closed-form formulas for the Mean Time To Failure of each topology. The …
引用总数
2016201720182019202020212022202320245868294102
学术搜索中的文章
RDS Couto, S Secci, MEM Campista, LHMK Costa - Journal of Network and Systems Management, 2016