Purpose
To examine factors associated with false‐negative cardiovascular magnetic resonance (MR) perfusion studies within the large prospective Clinical Evaluation of MR imaging in Coronary artery disease (CE‐MARC) study population. Myocardial perfusion MR has excellent diagnostic accuracy to detect coronary heart disease (CHD). However, causes of false‐negative MR perfusion studies are not well understood.
Materials and Methods
CE‐MARC prospectively recruited patients with suspected CHD and mandated MR, myocardial perfusion scintigraphy, and invasive angiography. This subanalysis identified all patients with significant coronary stenosis by quantitative coronary angiography (QCA) and MR perfusion (1.5T, T1‐weighted gradient echo), using the original blinded image read. We explored patient and imaging characteristics related to false‐negative or true‐positive MR perfusion results, with …