Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart DR Messroghli, A Radjenovic, S Kozerke, DM Higgins, MU Sivananthan, ... Magnetic Resonance in Medicine: An Official Journal of the International …, 2004 | 1657 | 2004 |
Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study D Dabir, N Child, A Kalra, T Rogers, R Gebker, A Jabbour, S Plein, CY Yu, ... Journal of Cardiovascular Magnetic Resonance 16 (1), 69, 2014 | 387 | 2014 |
Human Myocardium: Single-Breath-hold MR T1 Mapping with High Spatial Resolution—Reproducibility Study1 DR Messroghli, S Plein, DM Higgins, K Walters, TR Jones, JP Ridgway, ... Radiology 238 (3), 1004-1012, 2006 | 302 | 2006 |
Native T1 in discrimination of acute and convalescent stages in patients with clinical diagnosis of myocarditis: a proposed diagnostic algorithm using CMR R Hinojar, L Foote, E Arroyo Ucar, T Jackson, A Jabbour, CY Yu, ... JACC: Cardiovascular Imaging 8 (1), 37-46, 2015 | 229 | 2015 |
Cine MRI using steady state free precession in the radial long axis orientation is a fast accurate method for obtaining volumetric data of the left ventricle TN Bloomer, S Plein, A Radjenovic, DM Higgins, TR Jones, JP Ridgway, ... Journal of Magnetic Resonance Imaging: An Official Journal of the …, 2001 | 134 | 2001 |
T1 measurement using a short acquisition period for quantitative cardiac applications DM Higgins, JP Ridgway, A Radjenovic, UM Sivananthan, MA Smith Medical physics 32 (6Part1), 1738-1746, 2005 | 74 | 2005 |
Comparison of fast acquisition strategies in whole‐heart four‐dimensional flow cardiac MR: Two‐center, 1.5 Tesla, phantom and in vivo validation study P Garg, JJM Westenberg, PJ van den Boogaard, PP Swoboda, R Aziz, ... Journal of Magnetic Resonance Imaging 47 (1), 272-281, 2018 | 72 | 2018 |
Dark-blood late gadolinium enhancement without additional magnetization preparation RJ Holtackers, A Chiribiri, T Schneider, DM Higgins, RM Botnar Journal of Cardiovascular Magnetic Resonance 19 (1), 64, 2016 | 69 | 2016 |
Aortic stiffness and interstitial myocardial fibrosis by native T1 are independently associated with left ventricular remodeling in patients with dilated cardiomyopathy VO Puntmann, E Arroyo Ucar, R Hinojar Baydes, NB Ngah, YS Kuo, ... Hypertension 64 (4), 762-768, 2014 | 66 | 2014 |
Review of T1 mapping methods: comparative effectiveness including reproducibility issues DM Higgins, JC Moon Current Cardiovascular Imaging Reports 7, 1-10, 2014 | 64 | 2014 |
Investigating the quantitative fidelity of prospectively undersampled chemical shift imaging in muscular dystrophy with compressed sensing and parallel imaging reconstruction KG Hollingsworth, DM Higgins, M McCallum, L Ward, A Coombs, V Straub Magnetic resonance in medicine 72 (6), 1610-1619, 2014 | 55 | 2014 |
Improving highly accelerated fat fraction measurements for clinical trials in muscular dystrophy: origin and quantitative effect of R2* changes T Loughran, DM Higgins, M McCallum, A Coombs, V Straub, ... Radiology 275 (2), 570-578, 2015 | 53 | 2015 |
Accelerating MR imaging liver steatosis measurement using combined compressed sensing and parallel imaging: a quantitative evaluation LW Mann, DM Higgins, CN Peters, S Cassidy, KK Hodson, A Coombs, ... Radiology 278 (1), 247-256, 2016 | 50 | 2016 |
Towards accurate and precise T 1 and extracellular volume mapping in the myocardium: a guide to current pitfalls and their solutions D Cameron, VS Vassiliou, DM Higgins, PD Gatehouse Magnetic Resonance Materials in Physics, Biology and Medicine 31, 143-163, 2018 | 34 | 2018 |
Sensitivity of quantitative myocardial dynamic contrast‐enhanced MRI to saturation pulse efficiency, noise and t1 measurement error: Comparison of nonlinearity … DA Broadbent, JD Biglands, DP Ripley, DM Higgins, JP Greenwood, ... Magnetic Resonance in Medicine 75 (3), 1290-1300, 2016 | 29 | 2016 |
Susceptibility-weighted cardiovascular magnetic resonance in comparison to T2 and T2 star imaging for detection of intramyocardial hemorrhage following acute myocardial … A Kidambi, JD Biglands, DM Higgins, DP Ripley, A Zaman, DA Broadbent, ... Journal of Cardiovascular Magnetic Resonance 16, 1-11, 2014 | 29 | 2014 |
T1 mapping performance and measurement repeatability: results from the multi-national T1 mapping standardization phantom program (T1MES) G Captur, A Bhandari, R Brühl, B Ittermann, KE Keenan, Y Yang, ... Journal of Cardiovascular Magnetic Resonance 22 (1), 31, 2020 | 28 | 2020 |
The effect of changes to MOLLI scheme on T1 mapping and extra cellular volume calculation in healthy volunteers with 3 tesla cardiovascular magnetic resonance imaging AK McDiarmid, DA Broadbent, DM Higgins, PP Swoboda, A Kidambi, ... Quantitative imaging in medicine and surgery 5 (4), 503, 2015 | 28 | 2015 |
Single bolus versus split dose gadolinium administration in extra-cellular volume calculation at 3 Tesla AK McDiarmid, PP Swoboda, B Erhayiem, DP Ripley, A Kidambi, ... Journal of Cardiovascular Magnetic Resonance 17, 1-6, 2015 | 26 | 2015 |
Quality assurance of quantitative cardiac T1-mapping in multicenter clinical trials–A T1 phantom program from the hypertrophic cardiomyopathy registry (HCMR) study Q Zhang, K Werys, IA Popescu, L Biasiolli, NAB Ntusi, M Desai, ... International journal of cardiology 330, 251-258, 2021 | 25 | 2021 |