Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report) H de Las Heras Gala, A Torresin, A Dasu, O Rampado, H Delis, IH Girón, ... Physica Medica 39, 67-72, 2017 | 72 | 2017 |
Radiation doses in examination of lower third molars with computed tomography and conventional radiography A Ohman, L Kull, J Andersson, L Flygare Dentomaxillofacial radiology 37 (8), 445-452, 2008 | 60 | 2008 |
Upper limits of the photon fluence rate on CT detectors: case study on a commercial scanner M Persson, R Bujila, P Nowik, H Andersson, L Kull, J Andersson, ... Medical physics 43 (7), 4398-4411, 2016 | 47 | 2016 |
Application of the two-dose-rate method for general recombination correction for liquid ionization chambers in continuous beams J Andersson, H Tölli Physics in Medicine & Biology 56 (2), 299, 2010 | 28 | 2010 |
Dosimetric quantities and effective dose in medical imaging: a summary for medical doctors E Vano, G Frija, R Loose, G Paulo, E Efstathopoulos, C Granata, ... Insights into imaging 12, 1-9, 2021 | 24 | 2021 |
Estimation of patient skin dose in fluoroscopy: summary of a joint report by AAPM TG357 and EFOMP J Andersson, DR Bednarek, W Bolch, T Boltz, H Bosmans, ... Medical Physics 48 (7), e671-e696, 2021 | 19 | 2021 |
A comparison of different experimental methods for general recombination correction for liquid ionization chambers J Andersson, FJ Kaiser, F Gómez, O Jäkel, J Pardo-Montero, H Tölli Physics in Medicine & Biology 57 (21), 7161, 2012 | 18 | 2012 |
On the property of measurements with the PTW microLion chamber in continuous beams J Andersson, E Johansson, H Tölli Medical physics 39 (8), 4775-4787, 2012 | 15 | 2012 |
Estimating Patient Organ Dosewith Computed Tomography: A Review of Present Methodologyand Required DICOM Information: A Joint Report ofAAPM Task Group 246 and the European … J Andersson, W Pavlicek, R Al-Senan, W Bolch, H Bosmans, D Cody, ... American Association of Physicists in Medicine, 2019 | 13 | 2019 |
Applying three different methods of measuring CTDIfree air to the extended CTDI formalism for wide‐beam scanners (IEC 60601–2–44): A comparative study R Bujila, L Kull, M Danielsson, J Andersson Journal of applied clinical medical physics 19 (4), 281-289, 2018 | 13 | 2018 |
Influence of lead apron shielding on absorbed doses from cone-beam computed tomography D Rottke, J Andersson, KI Ejima, K Sawada, D Schulze Radiation protection dosimetry 175 (1), 110-117, 2017 | 13 | 2017 |
Proton stopping power prediction based on dual‐energy CT‐generated virtual monoenergetic images T Näsmark, J Andersson Medical Physics 48 (9), 5232-5243, 2021 | 12 | 2021 |
Artificial intelligence and the medical physics profession-A Swedish perspective J Andersson, T Nyholm, C Ceberg, A Almén, P Bernhardt, A Fransson, ... Physica Medica 88, 218-225, 2021 | 12 | 2021 |
Characterization of HPGe detectors using computed tomography A Hedman, JB Gogani, M Granström, L Johansson, JS Andersson, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2015 | 12 | 2015 |
Liquid ionization chamber initial recombination dependence on LET for electrons and photons E Johansson, J Andersson, L Johansson, H Tölli Physics in Medicine & Biology 58 (12), 4225, 2013 | 11 | 2013 |
The dosimetric impact of including the patient table in CT dose estimates P Nowik, R Bujila, L Kull, J Andersson, G Poludniowski Physics in Medicine & Biology 62 (23), N538, 2017 | 9 | 2017 |
Estimating Patient Organ Dose with Computed Tomography: A Review of Present Methodology and Required DICOM Information A Joint Report of AAPM Task Group 246 and the European … J Andersson, W Pavlicek, R Al-Senan, D Cody, R Dixon, P Columbo, ... (No Title), 2019 | 8 | 2019 |
Notifications and alerts in patient dose values for computed tomography and fluoroscopy-guided interventional procedures E Vano, R Loose, G Frija, G Paulo, E Efstathopoulos, C Granata, ... European Radiology 32 (8), 5525-5531, 2022 | 5 | 2022 |
Source modeling for Monte Carlo dose calculation of CT examinations with a radiotherapy treatment planning system HE Källman, R Holmberg, J Andersson, L Kull, E Tranéus, A Ahnesjö Medical Physics 43 (11), 6118-6128, 2016 | 5 | 2016 |
Ion recombination in liquid ionization chambers: development of an experimental method to quantify general recombination J Andersson Umeå universitet, 2013 | 4 | 2013 |