The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers D Giansanti, G Maccioni, V Macellari IEEE transactions on biomedical engineering 52 (7), 1271-1277, 2005 | 174 | 2005 |
Is it feasible to reconstruct body segment 3-D position and orientation using accelerometric data? D Giansanti, V Macellari, G Maccioni, A Cappozzo IEEE transactions on biomedical engineering 50 (4), 476-483, 2003 | 159 | 2003 |
Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturography D Giansanti, G Maccioni, S Cesinaro, F Benvenuti, V Macellari Medical engineering & physics 30 (3), 367-372, 2008 | 81 | 2008 |
New neural network classifier of fall-risk based on the Mahalanobis distance and kinematic parameters assessed by a wearable device D Giansanti, V Macellari, G Maccioni Physiological measurement 29 (3), N11, 2008 | 77 | 2008 |
Telemonitoring and telerehabilitation of patients with Parkinson’s disease: health technology assessment of a novel wearable step counter D Giansanti, V Macellari, G Maccioni Telemedicine and e-Health 14 (1), 76-83, 2008 | 73 | 2008 |
Energetic assessment of trunk postural modifications induced by a wearable audio-biofeedback system D Giansanti, M Dozza, L Chiari, G Maccioni, A Cappello Medical engineering & physics 31 (1), 48-54, 2009 | 67 | 2009 |
Inertial measurement units furnish accurate trunk trajectory reconstruction of the sit-to-stand manoeuvre in healthy subjects D Giansanti, G Maccioni, F Benvenuti, V Macellari Medical & biological engineering & computing 45, 969-976, 2007 | 65 | 2007 |
Physiological motion monitoring: a wearable device and adaptative algorithm for sit-to-stand timing detection D Giansanti, G Maccioni Physiological Measurement 27 (8), 713, 2006 | 52 | 2006 |
Toward the design of a wearable system for fall-risk detection in telerehabilitation D Giansanti, S Morelli, G Maccioni, G Costantini Telemedicine and e-Health 15 (3), 296-299, 2009 | 51 | 2009 |
Virtual microscopy and digital cytology: state of the art D Giansanti, M Grigioni, G D'Avenio, S Morelli, G Maccioni, A Bondi, ... Annali dell'Istituto superiore di sanità 46, 115-122, 2010 | 44 | 2010 |
A novel approach to mechanical foot stimulation during human locomotion under body weight support S Gravano, YP Ivanenko, G Maccioni, V Macellari, RE Poppele, ... Human Movement Science 30 (2), 352-367, 2011 | 41 | 2011 |
An experience of health technology assessment in new models of care for subjects with Parkinson’s disease by means of a new wearable device D Giansanti, G Maccioni, S Morelli TELEMEDICINE and e-HEALTH 14 (5), 467-472, 2008 | 37 | 2008 |
Comparison of three different kinematic sensor assemblies for locomotion study D Giansanti, G Maccioni Physiological Measurement 26 (5), 689, 2005 | 37 | 2005 |
Development and testing of a wearable Integrated Thermometer sensor for skin contact thermography D Giansanti, G Maccioni Medical engineering & physics 29 (5), 556-565, 2007 | 28 | 2007 |
Measurement device for ankle joint kinematic and dynamic characterisation C Giacomozzi, S Cesinaro, F Basile, G De Angelis, D Giansanti, ... Medical and Biological Engineering and Computing 41, 486-493, 2003 | 22 | 2003 |
New wearable system for the step counting based on the codivilla-spring for daily activity monitoring in stroke rehabilitation D Giansanti, Y Tiberi, G Maccioni 2008 30th Annual International Conference of the IEEE Engineering in …, 2008 | 19 | 2008 |
Guidlines for calibration and drift compensation of a wearable device with rate-gyroscopes and accelerometers D Giansanti, G Maccioni, V Macellari 2007 29th Annual International Conference of the IEEE Engineering in …, 2007 | 18 | 2007 |
Toward the design of a wearable system for the remote monitoring of epileptic crisis D Giansanti, G Ricci, G Maccioni Telemedicine and e-Health 14 (10), 1130-1135, 2008 | 17 | 2008 |
A comparative study for the development of a thermal odoscope for the wearable dynamic thermography monitoring D Giansanti, G Maccioni, GE Gigante Medical engineering & physics 28 (4), 363-371, 2006 | 16 | 2006 |
Classification of sit-to-stand locomotion task based on spectral analysis of waveforms generated by accelerometric transducer G Costantini, M Carota, G Maccioni, D Giansanti Electronics letters 42 (3), 147-148, 2006 | 13 | 2006 |