关注
Ivana Drobnjak
Ivana Drobnjak
Professor of Computational Healthcare, University College London
在 ucl.ac.uk 的电子邮件经过验证
标题
引用次数
引用次数
年份
Advances in functional and structural MR image analysis and implementation as FSL
SM Smith, M Jenkinson, ..., I Drobnjak, ..., PM Matthews
Neuroimage 23, S208-S219, 2004
145762004
Changes in connectivity profiles define functionally distinct regions in human medial frontal cortex
H Johansen-Berg, TEJ Behrens, MD Robson, I Drobnjak, ..., PM Matthews
Proceedings of the National Academy of Sciences 101 (36), 13335-13340, 2004
7772004
Towards a comprehensive framework for movement and distortion correction of diffusion MR images: Within volume movement
JLR Andersson, MS Graham, I Drobnjak, H Zhang, N Filippini, M Bastiani
Neuroimage 152, 450-466, 2017
3372017
Conventions and nomenclature for double diffusion encoding NMR and MRI
N Shemesh, SN Jespersen, ..., I Drobnjak, ..., CF Westin
Magnetic resonance in medicine 75 (1), 82-87, 2016
2462016
Resolution limit of cylinder diameter estimation by diffusion MRI: The impact of gradient waveform and orientation dispersion
M Nilsson, S Lasič, I Drobnjak, D Topgaard, CF Westin
NMR in Biomedicine 30 (7), e3711, 2017
1642017
PGSE, OGSE, and sensitivity to axon diameter in diffusion MRI: Insight from a simulation study
I Drobnjak, H Zhang, A Ianuş, E Kaden, DC Alexander
Magnetic resonance in medicine 75 (2), 688-700, 2016
1382016
Development of a functional magnetic resonance imaging simulator for modeling realistic rigid‐body motion artifacts
I Drobnjak, D Gavaghan, E Süli, J Pitt‐Francis, M Jenkinson
Magnetic Resonance in Medicine: An Official Journal of the International …, 2006
1262006
Realistic simulation of artefacts in diffusion MRI for validating post-processing correction techniques
MS Graham, I Drobnjak, H Zhang
NeuroImage 125, 1079-1094, 2016
1252016
Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data
JLR Andersson, MS Graham, I Drobnjak, H Zhang, J Campbell
Neuroimage 171, 277-295, 2018
1222018
Optimizing gradient waveforms for microstructure sensitivity in diffusion-weighted MR
I Drobnjak, B Siow, DC Alexander
Journal of Magnetic Resonance 206 (1), 41-51, 2010
1162010
Machine learning based compartment models with permeability for white matter microstructure imaging
GL Nedjati-Gilani, ..., I Drobnjak, CAMG Wheeler-Kingshott, DC Alexander
NeuroImage 150, 119-135, 2017
1042017
Quantitative assessment of the susceptibility artefact and its interaction with motion in diffusion MRI
MS Graham, I Drobnjak, M Jenkinson, H Zhang
PloS one 12 (10), e0185647, 2017
932017
Quality assessment of ambulatory ECG using wavelet entropy of the HRV signal
C Orphanidou, I Drobnjak
IEEE journal of biomedical and health informatics 21 (5), 1216-1223, 2016
702016
Gaussian phase distribution approximations for oscillating gradient spin echo diffusion MRI
A Ianuş, B Siow, I Drobnjak, H Zhang, DC Alexander
Journal of magnetic resonance 227, 25-34, 2013
692013
Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain
A Ianuş, SN Jespersen, TS Duarte, DC Alexander, I Drobnjak, N Shemesh
Neuroimage 183, 934-949, 2018
662018
The matrix formalism for generalised gradients with time-varying orientation in diffusion NMR
I Drobnjak, H Zhang, MG Hall, DC Alexander
Journal of Magnetic Resonance 210 (1), 151-157, 2011
662011
Model‐based estimation of microscopic anisotropy using diffusion MRI: a simulation study
A Ianuş, I Drobnjak, DC Alexander
NMR in Biomedicine 29 (5), 672-685, 2016
512016
A supervised learning approach for diffusion MRI quality control with minimal training data
MS Graham, I Drobnjak, H Zhang
NeuroImage 178, 668-676, 2018
502018
Estimation of pore size in a microstructure phantom using the optimised gradient waveform diffusion weighted NMR sequence
B Siow, I Drobnjak, A Chatterjee, MF Lythgoe, DC Alexander
Journal of Magnetic Resonance 214, 51-60, 2012
462012
Simulating the effects of time-varying magnetic fields with a realistic simulated scanner
I Drobnjak, GS Pell, M Jenkinson
Magnetic resonance imaging 28 (7), 1014-1021, 2010
442010
系统目前无法执行此操作,请稍后再试。
文章 1–20