Interventional dual‐energy imaging—Feasibility of rapid kV‐switching on a C‐arm CT system K Müller, S Datta, M Ahmad, JH Choi, T Moore, L Pung, C Niebler, ... Medical Physics 43 (10), 5537-5546, 2016 | 35 | 2016 |
Fully automatic head motion correction for interventional C-arm systems using fiducial markers K Müller, M Berger, J Choi, S Datta, S Gehrisch, T Moore, MP Marks, ... Proceedings of the 13th Fully Three-Dimensional Image Reconstruction in …, 2015 | 12 | 2015 |
Dynamic Measurement of Arterial Liver Perfusion With an Interventional C-Arm System S Datta, K Müller, T Moore, L Molvin, S Gehrisch, J Rosenberg, Y Saenz, ... Investigative Radiology 52 (8), 456-461, 2017 | 9 | 2017 |
The Role of Dual-Phase Cone-Beam CT in Predicting Short-Term Response after Transarterial Chemoembolization for Hepatocellular Carcinoma K Müller, S Datta, S Gehrisch, M Ahmad, MAA Mohammed, J Rosenberg, ... Journal of Vascular and Interventional Radiology 28 (2), 238-245, 2017 | 7 | 2017 |
Tibial cartilage creep during weight bearing: in vivo 3D CT assessment JH Choi, EJ McWalter, S Datta, K Mueller, A Maier, R Fahrig, ... Osteoarthritis and Cartilage 24, S104, 2016 | 5 | 2016 |
Systematic review of use of patient reported outcomes in interventional radiology S Datta, P Cramer, J Sung, D Wright, R Charalel Journal of the American College of Radiology, 2023 | 4 | 2023 |
Accuracy of flat panel detector CT with integrated navigational software with and without MR fusion for single-pass needle placement MC Mabray, S Datta, PV Lillaney, T Moore, S Gehrisch, JF Talbott, ... Journal of neurointerventional surgery 8 (7), 731-735, 2016 | 4 | 2016 |
In Vivo 3D Measurement of Time-dependent Human Knee Joint Compression and Cartilage Strain During Static Weight-Bearing JH Choi, EJ McWalter, S Datta, K Mueller, A Maier, GE Gold, M Levenston, ... Proceedings of the Orthopaedic Research Society (ORS) Annual Meeting, 2016 | 4 | 2016 |
Dual-energy C-arm CT in the angiographic suite S Datta, JH Choi, C Niebler, A Maier, R Fahrig, K Müller 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC …, 2015 | 4 | 2015 |
Adverse Events Associated with New Nitinol Venous-Labeled Stents: A Review of the FDA MAUDE Database J Yan, S Datta, A Kesselman, A Malhotra, K Scherer, V Wadhwa Journal of vascular and interventional radiology: JVIR 33 (10), 1261-1263, 2022 | 1 | 2022 |
Patient-Reported Outcomes: Updates since the 2017 Society of Interventional Radiology Foundation Research Consensus Panel RA Charalel, S Datta, JC Durack, NM Khilnani, R Salem, JB Spies, ... Journal of Vascular and Interventional Radiology 35 (4), 497-505, 2024 | | 2024 |
Abstract No. 201 Lesion Segmentation and 3D Fluoroscopic Overlay in Transbronchial Lung Biopsy S Datta, P Cramer, K Scherer, E Shostak, B Pua Journal of Vascular and Interventional Radiology 35 (3), S90-S91, 2024 | | 2024 |
Abstract No. 356 Safety and Short-Term Efficacy of Pulsed Electric Field Ablation P Cramer, S Datta, T McClure, B Currie, A Talenfeld, J Milsom, B Pua Journal of Vascular and Interventional Radiology 35 (3), S159, 2024 | | 2024 |
Abstract No. 591 Systematic review of use of patient-reported outcome measures in interventional radiology S Datta, P Cramer, J Sung, D Wright, R Charalel Journal of Vascular and Interventional Radiology 33 (6), S222, 2022 | | 2022 |
Comparison of angiographic features in sporadic and HHT-related brain AVMs S Datta, R Khangura, J Nelson, H Kim, D Cooke, S Hetts ANGIOGENESIS 22 (4), 603-603, 2019 | | 2019 |
Gastrointestinal Neuroendocrine Tumors: Clinical and Pathologic Correlates S Datta, A Sinha, B Kapoor Digestive Disease Interventions 3 (S 01), A028, 2019 | | 2019 |
Gastrointestinal Neuroendocrine Tumors: Clinical and Pathological Correlates S Datta, A Sinha, B Kapoor Digestive Disease Interventions 3 (01), 003-013, 2019 | | 2019 |
Utility of dual-phase cone-beam CT: Can it predict tumor response after super-selective TACE for HCC? K Mueller, S Datta, S Gehrisch, T Moore, M Ahmad, J Louie, D Wang, ... Journal of Vascular and Interventional Radiology 3 (27), S86, 2016 | | 2016 |
E-053 accuracy of flat panel detector ct with integrated navigational software with and without mr fusion for single pass needle placement in a deep brain stimulator phantom in … M Mabray, S Datta, P Lillaney, T Moore, S Gehrisch, J Talbott, P Larson, ... Journal of NeuroInterventional Surgery 7 (Suppl 1), A66-A66, 2015 | | 2015 |