Simple and customizable method for fabrication of high-aspect ratio microneedle molds using low-cost 3D printing KJ Krieger, N Bertollo, M Dangol, JT Sheridan, MM Lowery, ... Microsystems & nanoengineering 5 (1), 42, 2019 | 222 | 2019 |
Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface WR Walsh, N Bertollo, C Christou, D Schaffner, RJ Mobbs The Spine Journal 15 (5), 1041-1049, 2015 | 191 | 2015 |
Bio-resorbable polymer stents: a review of material progress and prospects S McMahon, N Bertollo, ED O’Cearbhaill, J Salber, L Pierucci, P Duffy, ... Progress in Polymer Science 83, 79-96, 2018 | 144 | 2018 |
Drilling of bone: practicality, limitations and complications associated with surgical drill-bits N Bertollo, WR Walsh Biomechanics in applications 4, 53-83, 2011 | 127 | 2011 |
A comparison of the thermal properties of 2-and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model N Bertollo, HRM Milne, LP Ellis, PC Stephens, RM Gillies, WR Walsh Clinical biomechanics 25 (6), 613-617, 2010 | 99 | 2010 |
Does PEEK/HA enhance bone formation compared with PEEK in a sheep cervical fusion model? WR Walsh, MH Pelletier, N Bertollo, C Christou, C Tan Clinical Orthopaedics and Related Research® 474, 2364-2372, 2016 | 87 | 2016 |
Corticosterone selectively targets endo-cortical surfaces by an osteoblast-dependent mechanism H Henneicke, M Herrmann, R Kalak, TC Brennan-Speranza, ... Bone 49 (4), 733-742, 2011 | 79 | 2011 |
In vivo implant fixation of carbon fiberreinforced PEEK hip prostheses in an ovine model I Nakahara, M Takao, S Bandoh, N Bertollo, WR Walsh, N Sugano Journal of Orthopaedic Research 31 (3), 485-492, 2013 | 78 | 2013 |
Influence of electron beam melting manufactured implants on ingrowth and shear strength in an ovine model N Bertollo, R Da Assuncao, NJ Hancock, A Lau, WR Walsh The Journal of arthroplasty 27 (8), 1429-1436, 2012 | 67 | 2012 |
Insights into the mechanics of solid conical microneedle array insertion into skin using the finite element method W Shu, H Heimark, N Bertollo, DJ Tobin, ED O'Cearbhaill, AN Annaidh Acta Biomaterialia 135, 403-413, 2021 | 61 | 2021 |
The effects of low-intensity pulsed ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model V Lovric, M Ledger, J Goldberg, W Harper, N Bertollo, MH Pelletier, ... Knee Surgery, Sports Traumatology, Arthroscopy 21, 466-475, 2013 | 59 | 2013 |
Biomechanical evaluation of four different transosseous-equivalent/suture bridge rotator cuff repairs M Maguire, J Goldberg, D Bokor, N Bertollo, MH Pelletier, W Harper, ... Knee Surgery, Sports Traumatology, Arthroscopy 19, 1582-1587, 2011 | 55 | 2011 |
Osseointegration of porous titanium implants with and without electrochemically deposited DCPD coating in an ovine model D Chen, N Bertollo, A Lau, N Taki, T Nishino, H Mishima, H Kawamura, ... Journal of Orthopaedic Surgery and Research 6, 1-8, 2011 | 54 | 2011 |
Performance of a knotless four-strand flexor tendon repair with a unidirectional barbed suture device: a dynamic ex vivo comparison TS Peltz, R Haddad, PJ Scougall, MP Gianoutsos, N Bertollo, WR Walsh Journal of Hand Surgery (European Volume) 39 (1), 30-39, 2014 | 41 | 2014 |
3-Fluted orthopaedic drills exhibit superior bending stiffness to their 2-fluted rivals: Clinical implications for targeting ability and the incidence of drill-bit failure N Bertollo, TK Gothelf, WR Walsh Injury 39 (7), 734-741, 2008 | 40 | 2008 |
Development and evaluation of 3Dprinted dry microneedle electrodes for surface electromyography KJ Krieger, J Liegey, EM Cahill, N Bertollo, MM Lowery, ED O'Cearbhaill Advanced Materials Technologies 5 (10), 2000518, 2020 | 39 | 2020 |
Bone ongrowth and mechanical fixation of implants in cortical and cancellous bone WR Walsh, MH Pelletier, N Bertollo, V Lovric, T Wang, P Morberg, ... Journal of Orthopaedic Surgery and Research 15, 1-10, 2020 | 37 | 2020 |
Effect of surgical fit on integration of cancellous bone and implant cortical bone shear strength for a porous titanium N Bertollo, M Matsubara, T Shinoda, D Chen, M Kumar, WR Walsh The Journal of arthroplasty 26 (7), 1000-1007, 2011 | 36 | 2011 |
The effect of sterilization on the dynamic mechanical properties of paired rabbit cortical bone N Russell, A Rives, N Bertollo, MH Pelletier, WR Walsh Journal of Biomechanics 46 (10), 1670-1675, 2013 | 31 | 2013 |
Lumbar spinal fusion with β-TCP granules and variable Escherichia coli–derived rhBMP-2 dose MH Pelletier, RA Oliver, C Christou, Y Yu, N Bertollo, H Irie, WR Walsh The Spine Journal 14 (8), 1758-1768, 2014 | 29 | 2014 |