Polymer gel dosimetry C Baldock, Y De Deene, S Doran, G Ibbott, A Jirasek, M Lepage, ... Physics in Medicine and Biology 55 (5), R1-63, 2010 | 1037 | 2010 |
A basic study of some normoxic polymer gel dosimeters Y De Deene, C Hurley, A Venning, K Vergote, M Mather, BJ Healy, ... Physics in Medicine and Biology 47 (19), 3441-3463, 2002 | 356 | 2002 |
Test liquids for quantitative MRI measurements of self‐diffusion coefficient in vivo PS Tofts, D Lloyd, CA Clark, GJ Barker, GJM Parker, P McConville, ... Magnetic Resonance in Medicine 43 (3), 368-374, 2000 | 322 | 2000 |
Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry C Baldock, RP Burford, N Billingham, GS Wagner, S Patval, RD Badawi, ... Physics in Medicine and Biology 43 (3), 695-702, 1998 | 278 | 1998 |
Investigation of the PAGAT polymer gel dosimeter using magnetic resonance imaging AJ Venning, B Hill, S Brindha, BJ Healy, C Baldock Physics in Medicine and Biology 50 (16), 3875-3888, 2005 | 253 | 2005 |
Advances in kilovoltage x-ray beam dosimetry R Hill, B Healy, L Holloway, Z Kuncic, D Thwaites, C Baldock Physics in Medicine & Biology 59 (6), R183, 2014 | 231 | 2014 |
Dose resolution in radiotherapy polymer gel dosimetry: effect of echo spacing in MRI pulse sequence C Baldock, M Lepage, SÅJ Bäck, PJ Murry, PM Jayasekera, D Porter, ... Physics in Medicine & Biology 46 (2), 449-460, 2001 | 216 | 2001 |
Dose–response stability and integrity of the dose distribution of various polymer gel dosimeters Y De Deene, A Venning, C Hurley, BJ Healy, C Baldock Physics in Medicine & Biology 47 (14), 2459-2470, 2002 | 198 | 2002 |
An experimental study of the dose response of polymer gel dosimeters imaged with x-ray computed tomography JV Trapp, SÅJ Bäck, M Lepage, G Michael, C Baldock Physics in Medicine and Biology 46 (11), 2939-2951, 2001 | 179 | 2001 |
Optimization of multiple spin–echo sequences for 3D polymer gel dosimetry Y De Deene, C Baldock Physics in Medicine & Biology 47 (17), 3117-3141, 2002 | 173 | 2002 |
Quantitative SPECT reconstruction using CT-derived corrections K Willowson, DL Bailey, C Baldock Physics in Medicine & Biology 53 (12), 3099, 2008 | 168 | 2008 |
Radiological properties of normoxic polymer gel dosimeters AJ Venning, KN Nitschke, PJ Keall, C Baldock Medical physics 32 (4), 1047-1053, 2005 | 164 | 2005 |
Experimental determination of the diffusion coefficient in two-dimensions in ferrous sulphate gels using the finite element method C Baldock, PJ Harris, AR Piercy, B Healy Australasian Physics & Engineering Sciences in Medicine 24 (1), 19-30, 2001 | 164 | 2001 |
Fourier transform Raman spectroscopy of polyacrylamide gels (PAGs) for radiation dosimetry C Baldock, L Rintoul, SF Keevil, JM Pope, GA George Physics in Medicine & Biology 43 (12), 3617-3627, 1998 | 158 | 1998 |
Ultrasound evaluation of polymer gel dosimeters M Mather, A Whittaker, C Baldock Physics in Medicine and Biology 47 (9), 1449-1458, 2002 | 153 | 2002 |
Dose resolution optimization of polymer gel dosimeters using different monomers M Lepage, PM Jayasakera, SÅJ Bäck, C Baldock Physics in Medicine & Biology 46 (10), 2665, 2001 | 132 | 2001 |
Radiological properties of the PRESAGE and PAGAT polymer dosimeters S Brown, A Venning, Y De Deene, P Vial, L Oliver, J Adamovics, ... Applied Radiation and Isotopes 66 (12), 1970-1974, 2008 | 130 | 2008 |
The relationship between radiation-induced chemical processes and transverse relaxation times in polymer gel dosimeters M Lepage, AK Whittaker, L Rintoul, SÅJ Bäck, C Baldock Physics in Medicine & Biology 46 (4), 1061, 2001 | 126 | 2001 |
The water equivalence of solid phantoms for low energy photon beams R Hill, Z Kuncic, C Baldock Medical physics 37 (8), 4355-4363, 2010 | 125 | 2010 |
A theoretical study of the radiological properties and water equivalence of Fricke and polymer gels used for radiation dosimetry P Keall, C Baldock Australasian Physical & Engineering Sciences in Medicine 22 (3), 85-91, 1999 | 122 | 1999 |