Ultrafast cardiac ultrasound imaging: technical principles, applications, and clinical benefits M Cikes, L Tong, GR Sutherland, J D’hooge JACC: Cardiovascular Imaging 7 (8), 812-823, 2014 | 230 | 2014 |
Multi-transmit beam forming for fast cardiac imaging—Experimental validation and in vivo application L Tong, A Ramalli, R Jasaityte, P Tortoli, J D'hooge IEEE transactions on medical imaging 33 (6), 1205-1219, 2014 | 148 | 2014 |
Multi-transmit beam forming for fast cardiac imaging-a simulation study L Tong, H Gao, J D'hooge IEEE transactions on ultrasonics, ferroelectrics, and frequency control 60 …, 2013 | 92 | 2013 |
Comparison of conventional parallel beamforming with plane wave and diverging wave imaging for cardiac applications: A simulation study L Tong, H Gao, HF Choi, J D'hooge IEEE transactions on ultrasonics, ferroelectrics, and frequency control 59 …, 2012 | 83 | 2012 |
Wide-angle tissue Doppler imaging at high frame rate using multi-line transmit beamforming: An experimental validation in vivo L Tong, A Ramalli, P Tortoli, G Fradella, S Caciolli, J Luo, J D'hooge IEEE transactions on Medical Imaging 35 (2), 521-528, 2015 | 43 | 2015 |
Real-time high-frame-rate cardiac B-mode and tissue Doppler imaging based on multiline transmission and multiline acquisition A Ramalli, A Dallai, F Guidi, L Bassi, E Boni, L Tong, G Fradella, ... IEEE transactions on ultrasonics, ferroelectrics, and frequency control 65 …, 2018 | 25 | 2018 |
Multiline transmit beamforming combined with adaptive apodization G Zurakhov, L Tong, A Ramalli, P Tortoli, J D’hooge, Z Friedman, D Adam IEEE transactions on ultrasonics, ferroelectrics, and frequency control 65 …, 2018 | 25 | 2018 |
A comparison of the performance of different multiline transmit setups for fast volumetric cardiac ultrasound A Ortega, J Provost, L Tong, P Santos, B Heyde, M Pernot, J D’hooge IEEE transactions on ultrasonics, ferroelectrics, and frequency control 63 …, 2016 | 23 | 2016 |
Performance optimization of lateral displacement estimation with spatial angular compounding Q He, L Tong, L Huang, J Liu, Y Chen, J Luo Ultrasonics 73, 9-21, 2017 | 22 | 2017 |
Acoustic output of multi-line transmit beamforming for fast cardiac imaging: a simulation study P Santos, L Tong, A Ortega, L Løvstakken, E Samset, J D'hooge IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 62 …, 2015 | 21 | 2015 |
Coded excitation for diverging wave cardiac imaging: A feasibility study F Zhao, L Tong, Q He, J Luo Physics in Medicine & Biology 62 (4), 1565, 2017 | 20 | 2017 |
Feasibility of multiplane-transmit beamforming for real-time volumetric cardiac imaging: A simulation study Y Chen, L Tong, A Ortega, J Luo, J D’hooge IEEE transactions on ultrasonics, ferroelectrics, and frequency control 64 …, 2017 | 20 | 2017 |
Multi transmit beams for fast cardiac imaging towards clinical routine A Ramalli, A Dallai, E Boni, L Bassi, V Meacci, M Giovannetti, L Tong, ... 2016 IEEE International Ultrasonics Symposium (IUS), 1-4, 2016 | 18 | 2016 |
Coded excitation for crosstalk suppression in multi-line transmit beamforming: Simulation study and experimental validation L Tong, Q He, A Ortega, A Ramalli, P Tortoli, J Luo, J D’hooge Applied Sciences 9 (3), 486, 2019 | 16 | 2019 |
Fast three-dimensional ultrasound cardiac imaging using multi-transmit beam forming: A simulation study L Tong, A Ortega, H Gao, J D'hooge 2013 IEEE International Ultrasonics Symposium (IUS), 1456-1459, 2013 | 13 | 2013 |
Plane wave imaging for cardiac motion estimation at high temporal resolution: a feasibility study in-vivo L Tong, J Hamilton, R Jasaityte, M Cikes, G Sutherland, J D'hooge 2012 IEEE International Ultrasonics Symposium, 228-231, 2012 | 8 | 2012 |
Multi-transmit beam forming for fast cardiac imaging L Tong, H Gao, HF Choi, J D'hooge 2011 IEEE International Ultrasonics Symposium, 140-143, 2011 | 8 | 2011 |
A GPU-based implementation of the spatial impulse response method for fast calculation of linear sound fields and pulse-echo responses of array transducers T Bruyneel, A Ortega, L Tong, J D'hooge 2013 IEEE International Ultrasonics Symposium (IUS), 367-369, 2013 | 7 | 2013 |
Safety of fast cardiac imaging using multiple transmit beams: Experimental verification A Ramalli, L Tong, J Luo, J D'hooge, P Tortoli 2014 IEEE International Ultrasonics Symposium, 1182-1185, 2014 | 6 | 2014 |
RF-based motion estimation using non-rigid image registration techniques: In-silico and in-vivo feasibility B Heyde, M Alessandrini, L Tong, J D'hooge 2014 IEEE International Ultrasonics Symposium, 2280-2283, 2014 | 6 | 2014 |