Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose CM Chen, SY Chu, MY Hsu, YL Liao, HY Tsai European radiology 24, 460-468, 2014 | 57 | 2014 |
Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back … CM Chen, YY Lin, MY Hsu, CF Hung, YL Liao, HY Tsai European Journal of Radiology 85 (9), 1666-1672, 2016 | 21 | 2016 |
Real-time estimation of dose reduction for pediatric CT using bismuth shielding NK Lai, YL Liao, TR Chen, YS Tyan, HY Tsai Radiation Measurements 46 (12), 2039-2043, 2011 | 20 | 2011 |
CT dose estimation using Gafchromic XR-CT film: Models comparison YL Liao, HC Kao, KS Chuang, CP Chen, HY Tsai Radiation measurements 46 (12), 2052-2055, 2011 | 11 | 2011 |
Bismuth shield affecting CT image quality and radiation dose in adjacent and distant zones relative to shielding surface: A phantom study YL Liao, NK Lai, YS Tyan, HY Tsai biomedical journal 42 (5), 343-351, 2019 | 10 | 2019 |
Automatic tube current modulation for volume scan in a 320-detector row CT scanner YL Liao, NK Lai, YS Tyan, KS Chuang, HY Tsai Radiation measurements 56, 328-332, 2013 | 8 | 2013 |
Secondary neutron ambient dose equivalent measurement of the wobbling system of a proton beam radiotherapy facility YL Liao, HH Chen, HY Chen, HC Huang, CY Yeh, HY Tsai Radiation Physics and Chemistry 137, 116-120, 2017 | 5 | 2017 |
Overbeaming and overlapping of volume-scan CT with tube current modulation in a 320-detector row CT scanner YL Liao, YS Chen, NK Lai, KS Chuang, HY Tsai Radiation Physics and Chemistry 104, 225-229, 2014 | 5 | 2014 |
Impact of using the new American College of Radiology digital mammography phantom on quality survey in modern digital mammography systems: Evidence from nationwide surveys in … YS Hwang, HY Tsai, YY Lin, YL Liao European Journal of Radiology 117, 9-14, 2019 | 2 | 2019 |
MO‐F‐CAMPUS‐I‐04: Patient Eye‐Lens Dose Reduction in Routine Brain CT Examinations Using Organ‐Based Tube Current Modulation and In‐Plane Bismuth Shielding HY Tsai, YL Liao, NK Lai, JR Chen, TR Chen Medical Physics 42 (6Part30), 3584-3584, 2015 | | 2015 |
Comparison of entrance surface dose of four routine CT examinations: Helical scan versus wide volume scan modes YL Liao, YS Chen, HY Tsai Physica Medica: European Journal of Medical Physics 30, e57-e58, 2014 | | 2014 |
SU‐FF‐I‐68: Survey of MSCT and SSCT Scanners in Taiwan: Technical Factors, CTDIs, and Effective Doses YL Liao, HY Tsai, JH Lin, CP Chen Medical Physics 36 (6Part3), 2450-2450, 2009 | | 2009 |
SU‐GG‐I‐76: Estimating Image Quality and Radiation Dose Reduction with In‐Plane Bismuth Shielding for CT Examinations: Phantom Study YL Liao, HY Tsai, YS Tyan, KY Cheng Medical Physics 35 (6Part4), 2659-2659, 2008 | | 2008 |