A review of fault detection and diagnosis methodologies on air-handling units Y Yu, D Woradechjumroen, D Yu Energy and Buildings 82, 550-562, 2014 | 327 | 2014 |
Performance of a coupled cooling system with earth-to-air heat exchanger and solar chimney H Li, Y Yu, F Niu, M Shafik, B Chen Renewable energy 62, 468-477, 2014 | 173 | 2014 |
Heat and mass transfer performance analysis and cooling capacity prediction of earth to air heat exchanger F Niu, Y Yu, D Yu, H Li Applied Energy 137, 211-221, 2015 | 155 | 2015 |
Investigation of a coupled geothermal cooling system with earth tube and solar chimney Y Yu, H Li, F Niu, D Yu Applied energy 114, 209-217, 2014 | 110 | 2014 |
Investigation on soil thermal saturation and recovery of an earth to air heat exchanger under different operation strategies F Niu, Y Yu, D Yu, H Li Applied Thermal Engineering 77, 90-100, 2015 | 85 | 2015 |
Extended virtual in-situ calibration method in building systems using Bayesian inference S Yoon, Y Yu Automation in Construction 73, 20-30, 2017 | 78 | 2017 |
Analysis of HVAC system oversizing in commercial buildings through field measurements D Woradechjumroen, Y Yu, H Li, D Yu, H Yang Energy and Buildings 69, 131-143, 2014 | 71 | 2014 |
Study on thermal performance of micro-channel separate heat pipe for telecommunication stations: Experiment and simulation L Ling, Q Zhang, Y Yu, Y Wu, S Liao international journal of refrigeration 59, 198-209, 2015 | 68 | 2015 |
Experimental study on the thermal characteristics of micro channel separate heat pipe respect to different filling ratio L Ling, Q Zhang, Y Yu, S Liao, Z Sha Applied Thermal Engineering 102, 375-382, 2016 | 66 | 2016 |
Virtual in-situ calibration method in building systems Y Yu, H Li Automation in Construction 59, 59-67, 2015 | 64 | 2015 |
Impacts of HVACR temperature sensor offsets on building energy performance and occupant thermal comfort S Yoon, Y Yu, J Wang, P Wang Building Simulation 12, 259-271, 2019 | 59 | 2019 |
Performance and thermal charging/discharging features of a phase change material assisted heat pump system in heating mode F Niu, L Ni, Y Yao, Y Yu, H Li Applied thermal engineering 58 (1-2), 536-541, 2013 | 59 | 2013 |
Reliability and availability analysis of a hybrid cooling system with water-side economizer in data center J Wang, Q Zhang, S Yoon, Y Yu Building and Environment 148, 405-416, 2019 | 49 | 2019 |
Strategies for virtual in-situ sensor calibration in building energy systems S Yoon, Y Yu Energy and Buildings 172, 22-34, 2018 | 49 | 2018 |
Hidden factors and handling strategies on virtual in-situ sensor calibration in building energy systems: Prior information and cancellation effect S Yoon, Y Yu Applied energy 212, 1069-1082, 2018 | 49 | 2018 |
Experimental investigation on the thermal performance of water cooled multi-split heat pipe system (MSHPS) for space cooling in modular data centers L Ling, Q Zhang, Y Yu, S Liao Applied Thermal Engineering 107, 591-601, 2016 | 48 | 2016 |
Virtual calibration of a supply air temperature sensor in rooftop air conditioning units D Yu, H Li, Y Yu, J Xiong HVAC&R Research 17 (1), 31-50, 2011 | 45 | 2011 |
Impact of uncertainties on the supervisory control performance of a hybrid cooling system in data center J Wang, Q Zhang, S Yoon, Y Yu Building and Environment 148, 361-371, 2019 | 44 | 2019 |
Multi-structural fast nonlinear model-based predictive control of a hydronic heating system Y Yu, V Loftness, D Yu Building and environment 69, 131-148, 2013 | 42 | 2013 |
Location and optimization analysis of capillary tube network embedded in active tuning building wall F Niu, Y Yu Energy 97, 36-45, 2016 | 40 | 2016 |