Low-cost photoacoustic NO2 trace gas monitoring at the pptV-level T Rück, R Bierl, FM Matysik Sensors and Actuators A: Physical 263, 501-509, 2017 | 56 | 2017 |
NO2 trace gas monitoring in air using off-beam quartz enhanced photoacoustic spectroscopy (QEPAS) and interference studies towards CO2, H2O and acoustic noise T Rück, R Bierl, FM Matysik Sensors and Actuators B: Chemical 255, 2462-2471, 2018 | 47 | 2018 |
Photoacoustic detection of acetone in N2 and synthetic air using a high power UV LED S Weigl, F Feldmeier, R Bierl, FM Matysik Sensors and Actuators B: Chemical 316, 128109, 2020 | 30 | 2020 |
Ultrafast photoinduced charge separation and recombination in weakly bound complexes between oxazine dyes and N, N-dimethylaniline S Schneider, W Stammler, R Bierl, W Jäger Chemical physics letters 219 (5-6), 433-439, 1994 | 29 | 1994 |
Graphene-enhanced plasmonic nanohole arrays for environmental sensing in aqueous samples C Genslein, P Hausler, EM Kirchner, R Bierl, AJ Baeumner, T Hirsch Beilstein Journal of Nanotechnology 7 (1), 1564-1573, 2016 | 21 | 2016 |
Effects of ambient parameters and cross-sensitivities from O2, CO2 and H2O on the photoacoustic detection of acetone in the UV region S Weigl, E Wittmann, T Rück, R Bierl, FM Matysik Sensors and Actuators B: Chemical 328, 129001, 2021 | 17 | 2021 |
A Comparison of Correlation and Zero-Crossing Based Techniques in Ultrasonic Measurement S Jobst, R Bierl 10th International Symposium on Applied Reconfigurable Computing (ARC'2014 …, 2014 | 13 | 2014 |
Development and characterization of a laboratory setup for photoacoustic NO2 determination based on the excitation of electronic 2B2 and 2B1 states using a low-cost … T Rück, R Bierl, FM Matysik Sensors and Actuators A: Physical 258, 193-200, 2017 | 11 | 2017 |
Detection of small molecules with surface plasmon resonance by synergistic plasmonic effects of nanostructured surfaces and graphene C Genslein, P Hausler, EM Kirchner, R Bierl, AJ Baeumner, T Hirsch Plasmonics in Biology and Medicine XIV 10080, 59-65, 2017 | 9 | 2017 |
Sub-picosecond transient grating measurements of the resonant energy transfer in cresyl violet solutions: Evidence for non-diffusive energy transport S Schneider, R Bierl, M Seischab Chemical physics letters 230 (4-5), 343-350, 1994 | 9 | 1994 |
Sub-Picosecond Grating Measurements of the Resonant Energy Transfer in Cresyl Violet Solutions R Bierl, M Seischab, S Schneider Laser in Forschung und Technik/Laser in Research and Engineering: Vorträge …, 1996 | | 1996 |
Sub-picosecond transient grating measurements of the resonant energy transfer in cresyl violet solutions. Evidence for non-diffusive energy transport (Chem. Phys. Letters 230 … S Schneider, R Bierl, M Seischab Chemical Physics Letters 233 (4), 489, 1995 | | 1995 |