Effects of glycerol co-solvent on the rate and form of polymer gel dose response A Jirasek, M Hilts, A Berman, KB McAuley Physics in Medicine & Biology 54 (4), 907, 2009 | 32 | 2009 |
Ultra‐high spatial resolution BOLD fMRI in humans using combined segmented‐accelerated VFA‐FLEET with a recursive RF pulse design AJL Berman, WA Grissom, T Witzel, S Nasr, DJ Park, K Setsompop, ... Magnetic resonance in medicine 85 (1), 120-139, 2021 | 26 | 2021 |
The effect of dissolved oxygen on the relaxation rates of blood plasma: implications for hyperoxia calibrated BOLD Y Ma, AJL Berman, GB Pike Magnetic Resonance in Medicine 76 (6), 1905-1911, 2016 | 26 | 2016 |
Modeling hyperoxia-induced BOLD signal dynamics to estimate cerebral blood flow, volume and mean transit time ME MacDonald, AJL Berman, EL Mazerolle, RJ Williams, GB Pike Neuroimage 178, 461-474, 2018 | 25 | 2018 |
Gas-free calibrated fMRI with a correction for vessel-size sensitivity AJL Berman, EL Mazerolle, ME MacDonald, NP Blockley, WM Luh, ... Neuroimage 169, 176-188, 2018 | 22 | 2018 |
The effect of dissolved oxygen on the susceptibility of blood AJL Berman, Y Ma, RD Hoge, GB Pike Magnetic resonance in medicine 75 (1), 363-371, 2016 | 19 | 2016 |
Age-related differences in cerebral blood flow and cortical thickness with an application to age prediction ME MacDonald, RJ Williams, D Rajashekar, RB Stafford, A Hanganu, ... Neurobiology of Aging 95, 131-142, 2020 | 17 | 2020 |
Volume‐of‐interest cone‐beam CT using a 2.35 MV beam generated with a carbon target JL Robar, D Parsons, A Berman, A MacDonald Medical physics 39 (7Part1), 4209-4218, 2012 | 17 | 2012 |
Simulations of the effect of diffusion on asymmetric spin echo based quantitative BOLD: An investigation of the origin of deoxygenated blood volume overestimation AJ Stone, NC Holland, AJL Berman, NP Blockley Neuroimage 201, 116035, 2019 | 15 | 2019 |
Dependence of the MR signal on the magnetic susceptibility of blood studied with models based on real microvascular networks X Cheng, AJL Berman, JR Polimeni, RB Buxton, L Gagnon, A Devor, ... Magnetic resonance in medicine 81 (6), 3865-3874, 2019 | 14 | 2019 |
Radiation exposure from CT scanning in the resuscitative phase of trauma care: a level one trauma centre experience L Beatty, E Furey, C Daniels, A Berman, JM Tallon Canadian Journal of Emergency Medicine 17 (6), 617-623, 2015 | 14 | 2015 |
Transverse signal decay under the weak field approximation: theory and validation AJL Berman, GB Pike Magnetic resonance in medicine 80 (1), 341-350, 2018 | 13 | 2018 |
The effect of dissolved oxygen on relaxation rates of blood plasma Y Ma, AJL Berman, GB Pike Proceedings 22nd Scientific Meeting International Society for Magnetic …, 2014 | 13 | 2014 |
PhysiCal: A rapid calibration scan for B0, B1+, coil sensitivity and Eddy current mapping SS Iyer, C Liao, Q Li, MK Manhard, A Berman, B Bilgic, K Setsompop Proceedings of the 28th Annual Meeting of ISMRM, Sydney/Virtual, 0661, 2020 | 9 | 2020 |
Interdatabase variability in cortical thickness measurements ME MacDonald, RJ Williams, ND Forkert, AJL Berman, CR McCreary, ... Cerebral Cortex 29 (8), 3282-3293, 2019 | 9 | 2019 |
Specific mass shift measurements in rubidium by Doppler-free two-photon transitions T Kong, A Gorelov, C Höhr, T Wiebe, A Chatwin-Davies, A Berman, ... Journal of Physics B: Atomic, Molecular and Optical Physics 44 (21), 215004, 2011 | 6 | 2011 |
High-resolution segmented-accelerated EPI using Variable Flip Angle FLEET with tailored slice profiles AJL Berman, T Witzel, WA Grissom, D Park, K Setsompop, JR Polimeni Proceedings of the 27th Annual Meeting of ISMRM. Montreal, Canada, 1169, 2019 | 5 | 2019 |
Simulations of the BOLD Non-Linearity Based on a Viscoelastic Model for Capillary and Vein Compliance JP Pfannmoeller, GA Hartung, X Cheng, A Berman, D Boas, JR Polimeni Proc Intl Soc Mag Reson Med 29, 2856, 2021 | 3 | 2021 |
VUDU: motion-robust, distortion-free multi-shot EPI J Cho, AJL Berman, B Gagoski, C Liao, J Stockmann, JR Polimeni, ... proceedings of ISMRM & SMRT Virtual Conference & Exhibition, 0002, 2021 | 3 | 2021 |
Segmented spin-echo BOLD fMRI using a variable flip angle FLEET acquisition with recursive RF pulse design for high spatial resolution fMRI AJL Berman, WA Grissom, T Witzel, D Park, O Veissmann, K Setsompop, ... Proceedings of 28th Annual Meeting of ISMRM. Paris, France, 5236, 2020 | 3 | 2020 |