Development of an equivalent diameter expression for vertical U-tubes used in ground-coupled heat pumps Y Gu, DL O'Neal Transactions-American Society of Heating Refrigerating and air Conditioning …, 1998 | 278 | 1998 |
A review of frost formation in simple geometries DL O'neal ASHRAE trans 91 (2), 267-282, 1985 | 221 | 1985 |
Performance of finned-tube heat exchangers under frosting conditions: I. Simulation model SN Kondepudi, DL O'Neal International journal of Réfrigération 16 (3), 175-180, 1993 | 160* | 1993 |
Thermal interference of adjacent legs in a vertical U-tube heat exchanger for a ground-coupled heat pump NK Muraya, DL O'Neal, WM Heffington ASHRAE Transactions-American Society of Heating Refrigerating …, 1996 | 134 | 1996 |
Effect of frost growth on the performance of louvered finned tube heat exchangers SN Kondepudi, DL O'Neal International Journal of Refrigeration 12 (3), 151-158, 1989 | 118 | 1989 |
The effects of frost growth on extended surface heat exchanger performance: a review SN Kondepudi, DL O’neal ASHRAE transactions 93 (2), 258-274, 1987 | 111 | 1987 |
Measurement of frost growth and density in a parallel plate geometry DL ONeal, DR Tree Ashrae Transactions 90 (2), 278-290, 1984 | 110 | 1984 |
Refrigeration system dynamics during the reverse cycle defrost DL O'NEAL ASHRAE Transactions 95, 689-698, 1989 | 109 | 1989 |
Modeling the effect of backfills on U-tube ground coil performance Y Gu, DL O'Neal Ashrae Transactions 104, 356, 1998 | 103 | 1998 |
Frosting performance of tube fin heat exchangers with wavy and corrugated fins SN Kondepudi, DL O'Neal Experimental Thermal and Fluid Science 4 (5), 613-618, 1991 | 102 | 1991 |
The effects of different fin configurations on the performance of finned-tube heat exchangers under frosting conditions SN Kondepudi, DL O’neal ASHRAE Trans 96 (2), 439-444, 1990 | 98 | 1990 |
An analytical solution to transient heat conduction in a composite region with a cylindrical heat source Y Gu, DL O’neal | 91 | 1995 |
Procedure for calibrating the DOE-2 simulation program to non-weather-dependent measured loads. DJ Bronson, SB Hinchey, JS Haberl, DL O'Neal ASHRAE Winter Meeting, Anaheim, CA, USA, 01/25-29/92, 636-652, 1992 | 90 | 1992 |
Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrost DL O'Neal, K Peterson, NK Anand International journal of refrigeration 14 (1), 52-57, 1991 | 90 | 1991 |
System performance characteristics of an air conditioner over a range of charging conditions M Farzad, DL O'neal International Journal of Refrigeration 14 (6), 321-328, 1991 | 85 | 1991 |
Defrost cycle performance for an air-source heat pump with a scroll and a reciprocating compressor V Payne, DL O'neal International Journal of Refrigeration 18 (2), 107-112, 1995 | 82 | 1995 |
Two-phase flow of R-22 through short-tube orifices Y Kim, DL O'neal ASHRAE transactions 100 (1), 323-334, 1994 | 81 | 1994 |
The effect of reduced evaporator air flow on the performance of a residential central air conditioner M Palani, D O'Neal, J Haberl Energy Systems Laboratory (http://esl. eslwin. tamu. edu), 1992 | 67 | 1992 |
Improving energy conservation retrofits with measured savings DE Claridge, JS Haberl, D Turner, DL O'Neal, WM Heffington, C Tombari, ... ASHRAE Journal (American Society of Heating, Refrigerating and Air …, 1991 | 61 | 1991 |
Failure analysis and redesign of the evaporator tubing in a Kimchi refrigerator S Woo, DL O’Neal, M Pecht Engineering Failure Analysis 17 (2), 369-379, 2010 | 54 | 2010 |