A capacitive electrode with fast recovery feature E Spinelli, M Haberman, P García, F Guerrero Physiological measurement 33 (8), 1277, 2012 | 65 | 2012 |
A two-wired ultra-high input impedance active electrode FN Guerrero, EM Spinelli IEEE transactions on biomedical circuits and systems 12 (2), 437-445, 2018 | 43 | 2018 |
Analysis and Simple Circuit Design of Double Differential EMG Active Electrode FN Guerrero, EM Spinelli, MA Haberman IEEE Transactions on Biomedical Circuits and Systems 10 (3), 787 - 795, 2015 | 35 | 2015 |
Surface EMG multichannel measurements using active, dry branched electrodes FN Guerrero, E Spinelli VI Latin American Congress on Biomedical Engineering CLAIB 2014, Paraná …, 2015 | 25 | 2015 |
A simple and reproducible capacitive electrode E Spinelli, F Guerrero, P García, M Haberman Medical Engineering & Physics 38 (3), 286-289, 2016 | 21 | 2016 |
High gain driven right leg circuit for dry electrode systems FN Guerrero, E Spinelli Medical Engineering & Physics 39, 117-122, 2017 | 17 | 2017 |
Capacitive driven–right–leg circuit design MA Haberman, EM Spinelli, PA García, FN Guerrero International Journal of Biomedical Engineering and Technology 17 (2), 115-126, 2015 | 8 | 2015 |
Sistema multicanal para adquisición de biopotenciales FN Guerrero, M Haberman, E Spinelli Revista Ingeniería Biomédica 8 (15), 18-26, 2014 | 8 | 2014 |
The biological amplifier E Spinelli, FN Guerrero Further Understanding of the Human Machine: The Road to Bioengineering, 463-500, 2017 | 6 | 2017 |
Three-electrode double-differential biopotential amplifier for surface EMG Measurements VA Catacora, FN Guerrero, EM Spinelli IEEE Transactions on Instrumentation and Measurement, 2023 | 5 | 2023 |
Size constraint to limit interference in drl-free single-ended biopotential measurements VA Catacora, FN Guerrero, EM Spinelli Journal of Medical and Biological Engineering 42 (3), 332-340, 2022 | 5 | 2022 |
Instrumentación para neuroprótesis vestibles FN Guerrero Universidad Nacional de La Plata, 2017 | 5 | 2017 |
A high input impedance single-ended input to balanced differential output amplifier EM Spinelli, MA Haberman, FN Guerrero, PA García IEEE Transactions on Instrumentation and Measurement 69 (4), 1682-1689, 2019 | 4 | 2019 |
A simple encoding method for Sigma-Delta ADC based biopotential acquisition systems FN Guerrero, EM Spinelli Journal of Medical Engineering & Technology 41 (7), 546-552, 2017 | 4 | 2017 |
Prototipo de Estimulación Funcional Eléctrica (FES) inalámbrico y de corriente constante para rehabilitación de extremidades R Ambrosio, J Borunda, E Sifuentes, A Heredia, F Guerrero, VR González Recuperado de http://www-optica. inaoep. mx/~ tecnologia_salud/2015/memorias …, 2015 | 4 | 2015 |
Real-time noise reduction through independent channel averaging for real-time biomedical signal acquisition FN Guerrero, MJ Oliva, EM Spinelli XI Southern Programmable Logic Conference (San Luis, 27 al 31 de marzo de 2023), 2023 | 3 | 2023 |
Biopotential acquisition systems FN Guerrero, EM Spinelli Medicine-Based Informatics and Engineering, 51-79, 2022 | 3 | 2022 |
WIMUMO project: a wearable open device for physiological signals acquisition FN Guerrero, R Madou, VA Catacora, MA Haberman, P García, AL Veiga, ... Sociedad Argentina de Bioingeniería, 2020 | 3 | 2020 |
Novel single-stage-switching neuromuscular stimulator SA González, F Guerrero, EM Spinelli VI Latin American Congress on Biomedical Engineering CLAIB 2014, Paraná …, 2015 | 3 | 2015 |
Protocolo experimental para análisis de usabilidad de periféricos de tipo apuntador R Madou, FN Guerrero, EM Spinelli VII Jornadas de Investigación, Transferencia y Extensión de la Facultad de …, 2023 | 2 | 2023 |