Estimation of natural circulation flow based on temperature in the FASSIP-02 large-scale test loop facility M Juarsa, AR Antariksawan, MH Kusuma, D Haryanto, N Putra IOP Conference Series: Earth and Environmental Science 105 (1), 012091, 2018 | 39 | 2018 |
Preliminary study on mass flow rate in passive cooling experimental simulation during transient using NC-queen apparatus M Juarsa, JH Purba, HM Kusuma, T Setiadipura, S Widodo Atom Indonesia 40 (3), 141-147, 2014 | 28 | 2014 |
Characteristics of screen mesh wick heat pipe with nano-fluid as passive cooling system WN Septiadi, N Putra, M Juarsa, IPA Putra, R Sahmura Atom Indonesia 39 (1), 24-31, 2013 | 26 | 2013 |
Simulation of operational conditions of FASSIP-02 natural circulation cooling system experimental loop AR Antariksawan, S Widodo, M Juarsa, D Haryanto, MH Kusuma, N Putra Jurnal Sains dan Teknologi Nuklir Indonesia (Indonesian Journal of Nuclear …, 2018 | 22 | 2018 |
Numerical study on natural circulation characteristics in FASSIP-02 experimental facility using RELAP5 code AR Antariksawan, S Widodo, M Juarsa, D Haryanto, MH Kusuma, N Putra IOP Conference Series: Earth and Environmental Science 105 (1), 012090, 2018 | 22 | 2018 |
Studi eksperimental laju aliran massa air berdasarkan perubahan sudut kemiringan untai pada kasus sirklasi alamiah menggunakan untai sirklasi alamiah (USSA-FT01) M Juarsa, A GOERITNO, A SUHERI, I SUMIRAT, D SAPTOADI, ... Jurnal Material dan Energi Indonesia, Jurusan Fisika FMIPA, Universitas …, 2011 | 22 | 2011 |
Experimental study on transient boiling heat transfer in an annulus with a narrow gap F Tanaka, M Juarsa, K Mishima, M Murase, T Nagae Journal of nuclear science and technology 41 (3), 279-284, 2004 | 15 | 2004 |
Calculation of boiling curves during rewetting of a hot vertical narrow channel J Zhang, F Tanaka, M Juarsa, K Mishima The 10th International Topical Meeting on Nuclear Reactor Thermal Hydraulics …, 2003 | 15 | 2003 |
An experimental analysis on nusselt number of natural circulation flow in transient condition based on the height differences between heater and cooler M Juarsa, JP Witoko, G Giarno, D Haryanto, JH Purba Atom Indonesia 44 (3), 123-130, 2018 | 14 | 2018 |
TRIGA 2000 Research Reactor Thermal-hydraulic Analysis Using RELAP/SCDAPSIM/MOD3. 4 AR Antariksawan, E Umar, S Widodo, M Juarsa, MH Kusuma International Journal of Technology 8 (4), 698-708, 2017 | 13 | 2017 |
Passive system simulation facility (FASSIP) loop for natural circulation study M Juarsa, GBHK GIARNO, D HARYANTO, J PRASETIO Proceeding of “Seminar Nasional Teknologi Energi Nuklir (SENTEN”. 2016 …, 2016 | 12 | 2016 |
Experimental study on the effect of gap size to CCFL and CHF in a vertical of narrow rectangular channel during quenching process M Juarsa, N Putra, WN Septiadi, AR Antariksawan Annals of Nuclear Energy 72 (Elsevier Ltd), 391 - 400, 2014 | 11 | 2014 |
Preliminary investigation on natural circulation flow using CFD and calculation base on experimental data pre-FASSIP-02 M Juarsa, AR Antariksawan, MH Kusuma, N Putra, PP Moniaga Journal of Physics: Conference Series 1198 (2), 022073, 2019 | 10 | 2019 |
Study on Boiling Heat Transfer During Reflooding Process in QUEEN Test Section M Juarsa, AR Antariksawan, J Prasetyo, I Wahyono, E Sumarno., ... Proceeding of ICAPP 2005, 15-19, 2005 | 10 | 2005 |
Analysis Of The Effect Of Elevation Difference Between Heater And Cooler Position In The Fassip-01 Test Loop Using Relap5 AS Ekariansyah, H Tjahjono, M Juarsa, S Widodo SIGMA EPSILON-Buletin Ilmiah Teknologi Keselamatan Reaktor Nuklir 19 (1), 2016 | 9 | 2016 |
Preliminary investigation of natural circulation stability in FASSIP-01 experimental facility using RELAP5 code AR Antariksawan, S Widodo, M Juarsa, G Giarno, MH Kusuma, N Putra AIP Conference Proceedings 2001 (1), 2018 | 8 | 2018 |
Studi Eksperimental Fenomena Sirkulasi Alamiah Aliran Satu-Fasa untuk Pengembangan PRHS Menggunakan Untai FASSIP M Juarsa Usulan Penelitian Tahun, 2015 | 8 | 2015 |
Study on boiling heat transfer under transient cooling in an annulus with a narrow gap M Juarsa Master Degree Thesis of Fundamental Energy Science. Kyoto University, 2003 | 8 | 2003 |
The performance of solar collector CPC (compound parabolic concentrator) type with three pipes covered by glass tubes YS Gaos, M Yulianto, M Juarsa, N Nurrohman, E Marzuki, D Yuliaji, ... AIP Conference Proceedings 1826 (1), 2017 | 7 | 2017 |
Laporan Analisis Keselamatan Eksperimen Post-LOCA menggunakan bagian uji QUEEN-II M Juarsa PTRKN BATAN, Serpong, 2007 | 7 | 2007 |