High-power and short-duration ablation for pulmonary vein isolation: biophysical characterization E Leshem, I Zilberman, CM Tschabrunn, M Barkagan, ... JACC: Clinical Electrophysiology 4 (4), 467-479, 2018 | 285 | 2018 |
High‐power and short‐duration ablation for pulmonary vein isolation: safety, efficacy, and long‐term durability M Barkagan, FM Contreras‐Valdes, E Leshem, AE Buxton, H Nakagawa, ... Journal of cardiovascular electrophysiology 29 (9), 1287-1296, 2018 | 136 | 2018 |
Impact of high-power short-duration radiofrequency ablation on long-term lesion durability for atrial fibrillation ablation HD Yavin, E Leshem, A Shapira-Daniels, J Sroubek, M Barkagan, ... Clinical Electrophysiology 6 (8), 973-985, 2020 | 109 | 2020 |
Infarct-related ventricular tachycardia: redefining the electrophysiological substrate of the isthmus during sinus rhythm E Anter, AG Kleber, M Rottmann, E Leshem, M Barkagan, CM Tschabrunn, ... JACC: Clinical Electrophysiology 4 (8), 1033-1048, 2018 | 101 | 2018 |
Histopathological characterization of radiofrequency ablation in ventricular scar tissue M Barkagan, E Leshem, A Shapira-Daniels, J Sroubek, AE Buxton, ... JACC: Clinical Electrophysiology 5 (8), 920-931, 2019 | 67 | 2019 |
Comparison of the Edwards SAPIEN S3 versus Medtronic Evolut-R devices for transcatheter aortic valve implantation J Ben-Shoshan, M Konigstein, D Zahler, G Margolis, E Chorin, A Steinvil, ... The American journal of cardiology 119 (2), 302-307, 2017 | 67 | 2017 |
Pulsed field ablation using a lattice electrode for focal energy delivery: biophysical characterization, lesion durability, and safety evaluation H Yavin, A Shapira-Daniels, M Barkagan, J Sroubek, D Shim, R Melidone, ... Circulation: Arrhythmia and Electrophysiology 13 (6), e008580, 2020 | 52 | 2020 |
Three-dimensional holographic visualization of high-resolution myocardial scar on HoloLens J Jang, CM Tschabrunn, M Barkagan, E Anter, B Menze, R Nezafat PloS one 13 (10), e0205188, 2018 | 45 | 2018 |
Mortality prediction following transcatheter aortic valve replacement: A quantitative comparison of risk scores derived from populations treated with either surgical or … A Halkin, A Steinvil, G Witberg, A Barsheshet, M Barkagan, A Assali, ... International journal of cardiology 215, 227-231, 2016 | 45 | 2016 |
A novel octaray multielectrode catheter for high‐resolution atrial mapping: electrogram characterization and utility for mapping ablation gaps J Sroubek, M Rottmann, M Barkagan, E Leshem, A Shapira‐Daniels, ... Journal of Cardiovascular Electrophysiology 30 (5), 749-757, 2019 | 41 | 2019 |
Modulating the baseline impedance: an adjunctive technique for maximizing radiofrequency lesion dimensions in deep and intramural ventricular substrate A Shapira-Daniels, M Barkagan, M Rottmann, J Sroubek, D Tugal, ... Circulation: Arrhythmia and Electrophysiology 12 (6), e007336, 2019 | 39 | 2019 |
Pseudoblock of the posterior mitral line with epicardial bridging connections is a frequent cause of complex perimitral tachycardias M Barkagan, A Shapira-Daniels, E Leshem, C Shen, E Anter Circulation: Arrhythmia and Electrophysiology 12 (1), e006933, 2019 | 38 | 2019 |
Expandable lattice electrode ablation catheter: a novel radiofrequency platform allowing high current at low density for rapid, titratable, and durable lesions M Barkagan, E Leshem, M Rottmann, J Sroubek, A Shapira-Daniels, ... Circulation: Arrhythmia and Electrophysiology 12 (4), e007090, 2019 | 33 | 2019 |
Impact of diabetes mellitus and hemoglobin A1C on outcome after transcatheter aortic valve implantation E Chorin, A Finkelstein, S Banai, G Aviram, M Barkagan, L Barak, G Keren, ... The American Journal of Cardiology 116 (12), 1898-1903, 2015 | 30 | 2015 |
Temperature-controlled radiofrequency ablation using irrigated catheters: maximizing ventricular lesion dimensions while reducing steam-pop formation E Leshem, I Zilberman, M Barkagan, A Shapira-Daniels, J Sroubek, ... Clinical Electrophysiology 6 (1), 83-93, 2020 | 27 | 2020 |
Impact of routine manual aspiration thrombectomy on outcomes of patients undergoing primary percutaneous coronary intervention for acute myocardial infarction: a meta-analysis M Barkagan, A Steinvil, Y Berchenko, A Finkelstein, G Keren, S Banai, ... International Journal of Cardiology 204, 189-195, 2016 | 25 | 2016 |
A novel multielectrode catheter for high-density ventricular mapping: electrogram characterization and utility for scar mapping M Barkagan, J Sroubek, A Shapira‐Daniels, H Yavin, J Jang, R Nezafat, ... EP Europace 22 (3), 440-449, 2020 | 22 | 2020 |
Comparison of triggering and nontriggering factors in ST-segment elevation myocardial infarction and extent of coronary arterial narrowing J Ben-Shoshan, Y Segman-Rosenstveig, Y Arbel, E Chorin, M Barkagan, ... The American Journal of Cardiology 117 (8), 1219-1223, 2016 | 14 | 2016 |
Increasing lesion dimensions of bipolar ablation by modulating the surface area of the return electrode A Younis, HD Yavin, K Higuchi, I Zilberman, J Sroubek, P Tchou, ... Clinical Electrophysiology 8 (4), 498-510, 2022 | 13 | 2022 |
Discordance in scar detection between electroanatomical mapping and cardiac MRI in an infarct swine model S Kucukseymen, H Yavin, M Barkagan, J Jang, A Shapira-Daniels, ... Clinical Electrophysiology 6 (11), 1452-1464, 2020 | 12 | 2020 |