关注
Andreas Havreland
Andreas Havreland
HBK
在 hbkworld.com 的电子邮件经过验证
标题
引用次数
引用次数
年份
CMUT electrode resistance design: Modeling and experimental verification by a row-column array
AS Havreland, M Engholm, BG Tomov, JA Jensen, O Hansen, ...
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 66 …, 2019
202019
BCB polymer based row-column addressed CMUT
AS Havreland, ML Ommen, C Silvestre, M Engholm, EV Thomsen
2017 IEEE International Ultrasonics Symposium (IUS), 1-4, 2017
152017
Micro-fabricated all optical pressure sensors
AS Havreland, SD Petersen, C Østergaard, K Reck-Nielsen, EV Thomsen
Microelectronic Engineering 174, 11-15, 2017
142017
Wafer bonded CMUT technology utilizing a Poly-Silicon-on-Insulator wafer
AS Havreland, M Engholm, RS Grass, JA Jensen, EV Thomsen
2019 IEEE International Ultrasonics Symposium (IUS), 758-761, 2019
102019
A row-column-addressed 2D probe with an integrated compound diverging lens
M Engholm, AS Havreland, EV Thomsen, C Beers, BG Tomov, JA Jensen
2018 IEEE International Ultrasonics Symposium (IUS), 1-4, 2018
72018
Analytical deflection profiles and pull-in voltage calculations of prestressed electrostatic actuated MEMS structures
AS Havreland, EV Thomsen
Journal of Microelectromechanical Systems 30 (4), 659-667, 2021
52021
Pull-in analysis of CMUT elements
AS Havreland, M Engholm, CV SØrensen, EV Thomsen
2020 IEEE International Ultrasonics Symposium (IUS), 1-4, 2020
52020
Large scale high voltage 192+ 192 row-column addressed CMUTs made with anodic bonding
RS Grass, K Steenberg, AS Havreland, M Engholm, EV Thomsen
2020 IEEE International Ultrasonics Symposium (IUS), 1-4, 2020
42020
Delay line separation of CMUT elements
AS Havreland, O Hansen, KF Pedersen, M Engholm, EV Thomsen
2020 IEEE International Ultrasonics Symposium (IUS), 1-4, 2020
32020
188+ 188 row–column addressed CMUT transducer for super resolution imaging
RS Grass, AS Havreland, M Engholm, JA Jensen, EV Thomsen
2019 IEEE International Ultrasonics Symposium (IUS), 746-749, 2019
32019
Wafer level characterization of row-column addressed CMUT arrays
EV Thomsen, K Steenberg, MG Petersen, M Weile, A Havreland, ...
2019 IEEE International Ultrasonics Symposium (IUS), 770-773, 2019
32019
Design of a novel zig-zag 192+ 192 row column addressed array transducer: A simulation study
M Schou, AS Havreland, M Engholm, MB Stuart, EV Thomsen, JA Jensen
2018 IEEE International Ultrasonics Symposium (IUS), 1-4, 2018
32018
A hand-held 190+ 190 row–column addressed cmut probe for volumetric imaging
RS Grass, M Engholm, AS Havreland, C Beers, ML Ommen, ...
IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control 2 …, 2022
22022
Micromachined integrated 2D transducers for ultrasound imaging
AS Havreland
DTU Health Technology, 2019
22019
Accurate Radiation Impedance Analysis for CMUT Design
SLG Pedersen, AS Havreland, O Hansen, EV Thomsen
2022 IEEE International Ultrasonics Symposium (IUS), 1-4, 2022
12022
384 Channel Modular Ultrasonic CMUT Probe for Rapid Prototyping
KF Pedersen, M Engholm, AS Havreland, LN Moesner, C Beers, ...
2020 IEEE International Ultrasonics Symposium (IUS), 1-3, 2020
12020
Secondary calibration using Gabrielsons method & COPA with background noise at a laboratory facility
JH Winther, A Havreland, TR Licht
Measurement: Sensors, 101758, 2024
2024
Linking Seismic Measurements to the International System of Units
L Klaus, M Schwardt, C Pilger, A Canu, F Larsonnier, JH Winther, ...
Pure and Applied Geophysics, 1-28, 2024
2024
Fabrication, Characterization and Modelling of Delay Line Based CMUTs
KF Pedersen, AS Havreland, EV Thomsen
2021 IEEE International Ultrasonics Symposium (IUS), 1-4, 2021
2021
系统目前无法执行此操作,请稍后再试。
文章 1–19