Formaldehyde in the indoor environment T Salthammer, S Mentese, R Marutzky Chemical reviews 110 (4), 2536-2572, 2010 | 1781 | 2010 |
Does e‐cigarette consumption cause passive vaping? T Schripp, D Markewitz, E Uhde, T Salthammer Indoor air 23 (1), 25-31, 2013 | 563 | 2013 |
Indoor aerosols: from personal exposure to risk assessment L Morawska, A Afshari, GN Bae, G Buonanno, CYH Chao, O Hänninen, ... Indoor air 23 (6), 462-487, 2013 | 461 | 2013 |
Impact of reaction products from building materials and furnishings on indoor air quality—a review of recent advances in indoor chemistry E Uhde, T Salthammer Atmospheric Environment 41 (15), 3111-3128, 2007 | 392 | 2007 |
Plastics additives in the indoor environment—flame retardants and plasticizers M Wensing, E Uhde, T Salthammer Science of the total environment 339 (1-3), 19-40, 2005 | 365 | 2005 |
Airborne particles in indoor environment of homes, schools, offices and aged care facilities: The main routes of exposure L Morawska, GA Ayoko, GN Bae, G Buonanno, CYH Chao, S Clifford, ... Environment international 108, 75-83, 2017 | 332 | 2017 |
Indoor environment: airborne particles and settled dust L Morawska, T Salthammer John Wiley & Sons, 2006 | 315* | 2006 |
Formaldehyde in the ambient atmosphere: from an indoor pollutant to an outdoor pollutant? T Salthammer Angewandte chemie international edition 52 (12), 3320-3327, 2013 | 278 | 2013 |
Partitioning of phthalates among the gas phase, airborne particles and settled dust in indoor environments CJ Weschler, T Salthammer, H Fromme Atmospheric Environment 42 (7), 1449-1460, 2008 | 262 | 2008 |
Smart homes and the control of indoor air quality A Schieweck, E Uhde, T Salthammer, LC Salthammer, L Morawska, ... Renewable and Sustainable Energy Reviews 94, 705-718, 2018 | 260 | 2018 |
Children's well-being at schools: Impact of climatic conditions and air pollution T Salthammer, E Uhde, T Schripp, A Schieweck, L Morawska, M Mazaheri, ... Environment international 94, 196-210, 2016 | 204 | 2016 |
Transdermal Uptake of Diethyl Phthalate and Di(n-butyl) Phthalate Directly from Air: Experimental Verification CJ Weschler, G Bekö, HM Koch, T Salthammer, T Schripp, J Toftum, ... Environmental health perspectives 123 (10), 928-934, 2015 | 196 | 2015 |
An investigation into the characteristics and formation mechanisms of particles originating from the operation of laser printers L Morawska, C He, G Johnson, R Jayaratne, T Salthammer, H Wang, ... Environmental science & technology 43 (4), 1015-1022, 2009 | 196 | 2009 |
Formaldehyde sources, formaldehyde concentrations and air exchange rates in European housings T Salthammer Building and environment 150, 219-232, 2019 | 191 | 2019 |
Organic indoor air pollutants T Salthammer, E Uhde Occurrence, measurement, evaluation, 2009 | 183 | 2009 |
Photocatalytic surface reactions on indoor wall paint T Salthammer, F Fuhrmann Environmental science & technology 41 (18), 6573-6578, 2007 | 178 | 2007 |
Airborne engineered nanoparticle mass sensor based on a silicon resonant cantilever HS Wasisto, S Merzsch, A Waag, E Uhde, T Salthammer, E Peiner Sensors and Actuators B: Chemical 180, 77-89, 2013 | 176 | 2013 |
Human exposure to ozone in school and office indoor environments H Salonen, T Salthammer, L Morawska Environment international 119, 503-514, 2018 | 174 | 2018 |
Phthalic esters in the indoor environment--test chamber studies on PVC-coated wallcoverings. E Uhde, M Bednarek, F Fuhrmann, T Salthammer Indoor Air 11 (3), 150-155, 2001 | 164* | 2001 |
Assessing human exposure to organic pollutants in the indoor environment T Salthammer, Y Zhang, J Mo, HM Koch, CJ Weschler Angewandte Chemie International Edition 57 (38), 12228-12263, 2018 | 160 | 2018 |