关注
Sam Beddar
标题
引用次数
引用次数
年份
In vivo dosimetry in external beam radiotherapy
B Mijnheer, S Beddar, J Izewska, C Reft
Medical physics 40 (7), 070903, 2013
4092013
Focal radiation therapy dose escalation improves overall survival in locally advanced pancreatic cancer patients receiving induction chemotherapy and consolidative chemoradiation
S Krishnan, AS Chadha, Y Suh, HC Chen, A Rao, P Das, BD Minsky, ...
International Journal of Radiation Oncology* Biology* Physics 94 (4), 755-765, 2016
3302016
Retroperitoneal soft tissue sarcoma: an analysis of radiation and surgical treatment
MT Ballo, GK Zagars, RE Pollock, RS Benjamin, BW Feig, JN Cormier, ...
International Journal of Radiation Oncology* Biology* Physics 67 (1), 158-163, 2007
2222007
In vivo dosimetry in brachytherapy
K Tanderup, S Beddar, CE Andersen, G Kertzscher, JE Cygler
Medical physics 40 (7), 070902, 2013
2132013
Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov …
M Guillot, L Gingras, L Archambault, S Beddar, L Beaulieu
Medical physics 38 (4), 2140-2150, 2011
1692011
Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy
L Beaulieu, S Beddar
Physics in Medicine & Biology 61 (20), R305, 2016
1672016
Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification
JC Polf, S Avery, DS Mackin, S Beddar
Physics in Medicine & Biology 60 (18), 7085, 2015
1492015
Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study
JC Polf, S Peterson, G Ciangaru, M Gillin, S Beddar
Physics in Medicine & Biology 54 (3), 731, 2009
1472009
3D prompt gamma imaging for proton beam range verification
E Draeger, D Mackin, S Peterson, H Chen, S Avery, S Beddar, JC Polf
Physics in Medicine & Biology 63 (3), 035019, 2018
1432018
Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation
JC Polf, S Peterson, M McCleskey, BT Roeder, A Spiridon, S Beddar, ...
Physics in Medicine & Biology 54 (22), N519, 2009
1422009
Intensity modulated radiation therapy (IMRT): differences in target volumes and improvement in clinically relevant doses to small bowel in rectal carcinoma
H Mok, CH Crane, MB Palmer, TM Briere, S Beddar, ME Delclos, ...
Radiation Oncology 6, 1-9, 2011
1412011
Toward a real-time in vivo dosimetry system using plastic scintillation detectors
L Archambault, TM Briere, F Pönisch, L Beaulieu, DA Kuban, A Lee, ...
International Journal of Radiation Oncology* Biology* Physics 78 (1), 280-287, 2010
1222010
On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry
F Therriault-Proulx, L Beaulieu, L Archambault, S Beddar
Physics in Medicine & Biology 58 (7), 2073, 2013
1172013
A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife
J Morin, D Béliveau‐Nadeau, E Chung, J Seuntjens, D Thériault, ...
Medical physics 40 (1), 011719, 2013
1152013
A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real‐time verification of 192Ir HDR brachytherapy
F Therriault‐Proulx, TM Briere, F Mourtada, S Aubin, S Beddar, ...
Medical physics 38 (5), 2542-2551, 2011
1132011
Duodenal toxicity after fractionated chemoradiation for unresectable pancreatic cancer
P Kelly, P Das, CC Pinnix, S Beddar, T Briere, M Pham, S Krishnan, ...
International Journal of Radiation Oncology* Biology* Physics 85 (3), e143-e149, 2013
1032013
In vivo dosimetry: trends and prospects for brachytherapy
G Kertzscher, A Rosenfeld, S Beddar, K Tanderup, JE Cygler
The British journal of radiology 87 (1041), 20140206, 2014
1012014
Radiotherapy for hepatocellular carcinoma: an overview
S Krishnan, LA Dawson, J Seong, Y Akine, S Beddar, TM Briere, ...
Annals of surgical oncology 15, 1015-1024, 2008
1012008
Scintillation dosimetry
S Beddar, L Beaulieu
CRC Press, 2016
1002016
Variation of for the small‐field dosimetric parameters percentage depth dose, tissue‐maximum ratio, and off‐axis ratio
P Francescon, S Beddar, N Satariano, IJ Das
Medical physics 41 (10), 101708, 2014
1002014
系统目前无法执行此操作,请稍后再试。
文章 1–20