Environmental monitoring and microclimatic control strategies in “La Specola” museum of Florence F Sciurpi, C Carletti, G Cellai, L Pierangioli Energy and Buildings 95, 190-201, 2015 | 89 | 2015 |
Experimental and environmental analysis of new sound-absorbing and insulating elements in recycled cardboard S Secchi, F Asdrubali, G Cellai, E Nannipieri, A Rotili, I Vannucchi Journal of Building Engineering 5, 1-12, 2016 | 76 | 2016 |
Effect of outdoor noise and façade sound insulation on indoor acoustic environment of Italian schools S Secchi, A Astolfi, G Calosso, D Casini, G Cellai, F Scamoni, C Scrosati, ... Applied Acoustics 126, 120-130, 2017 | 65 | 2017 |
Effectiveness of passive measures against climate change: Case studies in Central Italy L Pierangioli, G Cellai, R Ferrise, G Trombi, M Bindi Building Simulation 10, 459-479, 2017 | 47 | 2017 |
Transparent building envelope: windows and shading devices typologies for energy efficiency refurbishments G Cellai, C Carletti, F Sciurpi, S Secchi Building Refurbishment for Energy Performance: A Global Approach, 61-118, 2014 | 30 | 2014 |
Acoustic issues in open plan offices: A typological analysis S Delle Macchie, S Secchi, G Cellai Buildings 8 (11), 161, 2018 | 23 | 2018 |
Correlation between facade sound insulation and urban noise: A contribution to the acoustic classification of existing buildings D Casini, G Cellai, J Fogola, F Scamoni, S Secchi Building Acoustics 23 (3-4), 145-158, 2016 | 23 | 2016 |
The hygrometric behaviour of some artificial stone materials used as elements of masonry walls M Barsottelli, GF Cellai, F Fratini, C Manganelli Del Fà Materials and Structures 34, 211-216, 2001 | 22 | 2001 |
Acoustic wayfinding: A method to measure the acoustic contrast of different paving materials for blind people S Secchi, A Lauria, G Cellai Applied ergonomics 58, 435-445, 2017 | 20 | 2017 |
Sound transmission between rooms with curtain wall façades: a case study S Secchi, G Cellai, P Fausti, A Santoni, NZ Martello Building Acoustics 22 (3-4), 193-207, 2015 | 20 | 2015 |
The influence of daylighting in buildings with parameters nZEB: application to the case study for an office in Tuscany Mediterranean area C Carletti, G Cellai, L Pierangioli, F Sciurpi, S Secchi Energy Procedia 140, 339-350, 2017 | 16 | 2017 |
La progettazione delle condotte dell'aria ai fini della manutenzione Parte prima G Cellai CONDIZIONAMENTO DELL ARIA RISCALDAMENTO REFRIDGERAZIONE 41, 715-729, 1997 | 16 | 1997 |
Stone masonry buildings: Analysis of structural acoustic and energy performance within the seismic safety criteria A Schiavi, G Cellai, S Secchi, F Brocchi, A Grazzini, A Prato, F Mazzoleni Construction and building materials 220, 29-42, 2019 | 15 | 2019 |
Environmental monitoring and building simulation application to Vasari Corridor: preliminary results F Sciurpi, C Carletti, G Cellai, V Muratore, A Orsi, L Pierangioli, G Russo, ... Energy Procedia 133, 219-230, 2017 | 14 | 2017 |
Urban noise and required facade acoustic insulation of buildings: the case of some agglomerations in Italy D Casini, G Cellai, S Secchi, J Fogola, F Scamoni Proceedings of the 22nd International Congress on Sound and Vibration …, 2015 | 12 | 2015 |
A method to estimate students’ exposure to road traffic noise events S Secchi, G Brambilla, D Casini, G Cellai Environments 5 (3), 39, 2018 | 11 | 2018 |
Air quality and ductwork contamination: survey methodology and acceptable values. G Cellai, C Carletti, G Raffellini, G Altano, L Cennini | 11 | 2001 |
Analysis of direct and flanking sound transmission between rooms with curtain wall facades N ZUCCHERINI MARTELLO, S Secchi, P Fausti, G Cellai, A Santoni Energy Procedia 78 (November 2015), 164-169, 2015 | 8 | 2015 |
Uncertainty of faqade sound insulation meas-urements obtained by a round robin test: The influence of the low frequencies extension C Scrosati, F Scamoni, F Asdrubali, F D'Alessandro, E Moretti, A Astolfi, ... 22nd International Congress on Sound and Vibration, ICSV 2015, 2015 | 8 | 2015 |
La protezione acustica degli edifici: soluzioni tecniche e informazioni progettuali per il rispetto del DPCM 5/12/97 G Cellai, S Secchi, L Busa Alinea Editrice, 2005 | 8 | 2005 |