Accurate MTF measurement in digital radiography using noise response A Kuhls‐Gilcrist, A Jain, DR Bednarek, KR Hoffmann, S Rudin Medical physics 37 (2), 724-735, 2010 | 47 | 2010 |
Radiation protocol for three‐dimensional rotational angiography to limit procedural radiation exposure in the pediatric cardiac catheterization lab L Haddad, BR Waller, J Johnson, A Choudhri, V McGhee, D Zurakowski, ... Congenital Heart Disease 11 (6), 637-646, 2016 | 32 | 2016 |
A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems GK Yadava, AT Kuhls-Gilcrist, S Rudin, VK Patel, KR Hoffmann, ... Physics in Medicine & Biology 53 (18), 5107, 2008 | 32 | 2008 |
The solid state x-ray image intensifier (SSXII): An EMCCD-based x-ray detector A Kuhls-Gilcrist, G Yadava, V Patel, A Jain, DR Bednarek, S Rudin Medical Imaging 2008: Physics of Medical Imaging 6913, 192-201, 2008 | 26 | 2008 |
Generalized objective performance assessment of a new high-sensitivity microangiographic fluoroscopic (HSMAF) imaging system GK Yadava, S Rudin, AT Kuhls-Gilcrist, DR Bednarek Medical Imaging 2008: Physics of Medical Imaging 6913, 300-310, 2008 | 25 | 2008 |
Progress in the development of a new angiography suite including the high resolution micro-angiographic fluoroscope (MAF): a control, acquisition, processing, and image display … W Wang, CN Ionita, C Keleshis, A Kuhls-Gilcrist, A Jain, D Bednarek, ... Medical Imaging 2010: Physics of Medical Imaging 7622, 1716-1725, 2010 | 20 | 2010 |
Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and … A Jain, AT Kuhls-Gilcrist, SK Gupta, DR Bednarek, S Rudin Medical Imaging 2010: Physics of Medical Imaging 7622, 204-213, 2010 | 17 | 2010 |
Component analysis of a new Solid State X-ray Image Intensifier (SSXII) using photon transfer and Instrumentation Noise Equivalent Exposure (INEE) measurements A Kuhls-Gilcrist, DR Bednarek, S Rudin Medical Imaging 2009: Physics of Medical Imaging 7258, 407-416, 2009 | 14 | 2009 |
Clinical evaluation of a radio‐protective cream for the hands of the pediatric interventional cardiologist S Subramanian, BR Waller, N Winders, LE Bird, V Agrawal, D Zurakowski, ... Catheterization and Cardiovascular Interventions 89 (4), 709-716, 2017 | 13 | 2017 |
Component level modular design of a Solid State X-ray Image Intensifier for an M× N array Y Huang, B Qu, P Sharma, A Kuhls-Gilcrist, W Wang, AH Titus, ... IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2714-2717, 2010 | 10 | 2010 |
A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response A Kuhls-Gilcrist, DR Bednarek, S Rudin Medical Imaging 2010: Physics of Medical Imaging 7622, 1551-1559, 2010 | 8 | 2010 |
The solid state x-ray image intensifier (SSXII) in single photon counting (SPC) mode A Kuhls-Gilcrist, A Jain, R Daniel, S Rudin Medical Imaging 2010: Physics of Medical Imaging 7622, 569-577, 2010 | 8 | 2010 |
AAPM Task Group Report 238: 3D C‐arms with volumetric imaging capability M Supanich, J Siewerdsen, R Fahrig, K Farahani, GJ Gang, P Helm, ... Medical physics 50 (8), e904-e945, 2023 | 7 | 2023 |
AAPM Task Group Report 272: Comprehensive acceptance testing and evaluation of fluoroscopy imaging systems PJP Lin, AR Goode, FD Corwin, RF Fisher, S Balter, KA Wunderle, ... Medical physics 49 (4), e1-e49, 2022 | 7 | 2022 |
Use of 3‐D digital subtraction rotational angiography during cardiac catheterization of infants and adults with congenital heart diseases S Surendran, BR Waller, L Elijovich, V Agrawal, A Kuhls‐Gilcrist, ... Catheterization and Cardiovascular Interventions 90 (4), 618-625, 2017 | 7 | 2017 |
Improved contrast and spatial resolution with single photon counting (SPC) for an area X-ray imager, the newly developed high-resolution micro-angiographic fluoroscopic (MAF … A Jain, A Kuhls-Gilcrist, DR Bednarek, S Rudin 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC), 3012-3016, 2009 | 7 | 2009 |
Design, characterization, and modeling for a modular high-resolution solid-state x-ray image intensifier (ssxii) Y Huang, B Qu, A Jain, AT Kuhls-Gilcrist, AH Titus, AN Cartwright, ... IEEE Transactions on Nuclear Science 60 (1), 20-29, 2013 | 6 | 2013 |
Performance trade-off analysis comparing different front-end configurations for a digital x-ray imager A Kuhls-Gilcrist, A Jain, S Rudin, DR Bednarek IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2491-2494, 2010 | 5 | 2010 |
Novel multiplexer to enable multiple-module imaging with adjustable high spatial resolution and predetermined display bandwidth for array medical imaging systems P Sharma, AH Titus, B Qu, Y Huang, W Wang, A Kuhls-Gilcrist, ... IEEE Nuclear Science Symposuim & Medical Imaging Conference, 2134-2137, 2010 | 4 | 2010 |
SU‐FF‐I‐171: New High‐Resolution Detector Changer for a Clinical Fluoroscopic C‐Arm Unit W Wang, C Keleshis, A Kuhls‐Gilcrist, C Ionita, A Jain, D Bednarek, ... Medical Physics 36 (6Part5), 2474-2474, 2009 | 4 | 2009 |