Microfluidic flow focusing: Drop size and scaling in pressure versus flow‐rate‐driven pumping T Ward, M Faivre, M Abkarian, HA Stone Electrophoresis 26 (19), 3716-3724, 2005 | 467 | 2005 |
Swinging of red blood cells under shear flow M Abkarian, M Faivre, A Viallat Physical review letters 98 (18), 188302, 2007 | 427 | 2007 |
Geometrical focusing of cells in a microfluidic device: an approach to separate blood plasma M Faivre, M Abkarian, K Bickraj, HA Stone Biorheology 43 (2), 147-159, 2006 | 285 | 2006 |
Cellular-scale hydrodynamics M Abkarian, M Faivre, R Horton, K Smistrup, CA Best-Popescu, HA Stone Biomedical materials 3 (3), 034011, 2008 | 233 | 2008 |
High-speed microfluidic differential manometer for cellular-scale hydrodynamics M Abkarian, M Faivre, HA Stone Proceedings of the National Academy of Sciences 103 (3), 538-542, 2006 | 222 | 2006 |
Impact of surface-area-to-volume ratio, internal viscosity and membrane viscoelasticity on red blood cell deformability measured in isotonic condition C Renoux, M Faivre, A Bessaa, L Da Costa, P Joly, A Gauthier, P Connes Scientific reports 9 (1), 6771, 2019 | 73 | 2019 |
Drop production and tip-streaming phenomenon in a microfluidic flow-focusing device via an interfacial chemical reaction T Ward, M Faivre, HA Stone Langmuir 26 (12), 9233-9239, 2010 | 72 | 2010 |
Ultrasound internal tattooing O Couture, M Faivre, N Pannacci, A Babataheri, V Servois, P Tabeling, ... Medical physics 38 (2), 1116-1123, 2011 | 68 | 2011 |
Gel phase vesicles buckle into specific shapes F Quemeneur, C Quilliet, M Faivre, A Viallat, B Pépin-Donat Physical review letters 108 (10), 108303, 2012 | 44 | 2012 |
Magnetophoretic manipulation in microsystem using carbonyl iron-polydimethylsiloxane microstructures M Faivre, R Gelszinnis, J Degouttes, N Terrier, C Riviere, R Ferrigno, ... Biomicrofluidics 8 (5), 2014 | 40 | 2014 |
Mechanical signature of red blood cells flowing out of a microfluidic constriction is impacted by membrane elasticity, cell surface-to-volume ratio and diseases M Faivre, C Renoux, A Bessaa, L Da Costa, P Joly, A Gauthier, P Connes Frontiers in Physiology 11, 576, 2020 | 26 | 2020 |
Dielectrophoretic capture of low abundance cell population using thick electrodes J Marchalot, JF Chateaux, M Faivre, HC Mertani, R Ferrigno, AL Deman Biomicrofluidics 9 (5), 2015 | 25 | 2015 |
Coagulation dynamics of a blood sample by multiple scattering analysis M Faivre, P Peltié, A Planat-Chrétien, ML Cosnier, M Cubizolles, ... Journal of biomedical optics 16 (5), 057001-057001-9, 2011 | 22 | 2011 |
Device for characterizing the coagulation or sedimentation dynamics of a fluid such as blood or blood plasma P Pouteau, M Faivre, P Peltie, A Planat-Chretien US Patent 9,494,604, 2016 | 21 | 2016 |
Responsive Giant Vesicles Filled with Poly(N-isopropylacrylamide) Sols or Gels M Faivre, C Campillo, A Viallat, B Pepin-Donat Smart Colloidal Materials, 41-44, 2006 | 20 | 2006 |
Dual shape recovery of red blood cells flowing out of a microfluidic constriction A Amirouche, J Esteves, A Lavoignat, S Picot, R Ferrigno, M Faivre Biomicrofluidics 14 (2), 2020 | 18 | 2020 |
Anisotropic ferromagnetic polymer: A first step for their implementation in microfluidic systems D Le Roy, D Dhungana, L Ourry, M Faivre, R Ferrigno, A Tamion, ... AIP Advances 6 (5), 2016 | 16 | 2016 |
Effect of electrode material on the sensitivity of interdigitated electrodes used for Electrical Cell-Substrate Impedance Sensing technology J Martinez, A Montalibet, E Mcadams, M Faivre, R Ferrigno 2017 39th Annual International Conference of the IEEE Engineering in …, 2017 | 11 | 2017 |
Drops, vesicles and red blood cells: Deformability and behavior under flow M Faivre Université Joseph-Fourier-Grenoble I, 2006 | 11 | 2006 |
Influence of storage and buffer composition on the mechanical behavior of flowing red blood cells A Merlo, S Losserand, F Yaya, P Connes, M Faivre, S Lorthois, C Minetti, ... Biophysical Journal 122 (2), 360-373, 2023 | 5 | 2023 |