Optimal control of structures with semiactive-tuned mass dampers U Aldemir Journal of sound and vibration 266 (4), 847-874, 2003 | 119 | 2003 |
A new active control performance index for vibration control of three-dimensional structures A Yanik, U Aldemir, M Bakioglu Engineering Structures 62, 53-64, 2014 | 68 | 2014 |
Optimal control of linear buildings under seismic excitations U Aldemir, M Bakioglu, SS Akhiev Earthquake engineering & structural dynamics 30 (6), 835-851, 2001 | 68 | 2001 |
Control of structural response under earthquake excitation U Aldemir, A Yanik, M Bakioglu Computer‐Aided Civil and Infrastructure Engineering 27 (8), 620-638, 2012 | 65 | 2012 |
A simple active control algorithm for earthquake excited structures U Aldemir Computer‐Aided Civil and Infrastructure Engineering 25 (3), 218-225, 2010 | 49 | 2010 |
A new numerical algorithm for sub‐optimal control of earthquake excited linear structures M Bakioglu, U Aldemir International Journal for Numerical Methods in Engineering 50 (12), 2601-2616, 2001 | 48 | 2001 |
Active structural control based on the prediction and degree of stability U Aldemir, M Bakioglu Journal of Sound and Vibration 247 (4), 561-576, 2001 | 47 | 2001 |
Optimal control: basis for performance comparison of passive and semiactive isolation systems C Alhan, HP Gavin, U Aldemir Journal of Engineering Mechanics 132 (7), 705-713, 2006 | 41 | 2006 |
Optimal control of earthquake response using semiactive isolation HP Gavin, U Aldemir Journal of Engineering Mechanics 131 (8), 769-776, 2005 | 41 | 2005 |
Multipoint instantaneous optimal control of structures SS Akhiev, U Aldemir, M Bakioglu Computers & structures 80 (11), 909-917, 2002 | 39 | 2002 |
Causal semiactive control of seismic response U Aldemir Journal of Sound and Vibration 322 (4-5), 665-673, 2009 | 26 | 2009 |
A simple structural control model for earthquake excited structures A Yanik, U Aldemir Engineering Structures 182, 79-88, 2019 | 25 | 2019 |
Optimal semiactive control of structures with isolated base U Aldemir, HP Gavin International Applied Mechanics 42, 235-240, 2006 | 20 | 2006 |
Semiactive control of earthquake-excited structures U Aldemir, M Bakioglu Turkish Journal of Engineering & Environmental Sciences/Turk Muhendislik ve …, 2000 | 13 | 2000 |
Seismic vibration control of three dimensional structures with a simple approach A Yanik, U Aldemir, M Bakioglu J Vib Eng Technol 4 (3), 235-247, 2016 | 12 | 2016 |
Evaluation of disturbance weighting parameter of minimax attenuation problems U Aldemir Computer‐Aided Civil and Infrastructure Engineering 24 (4), 302-308, 2009 | 12 | 2009 |
Behavior and response of auto-adaptive seismic isolation H Gavin, U Aldemir, ITUI Fakultesi, MA Dali Proc. 3rd US-Japan Workshop in Urban Earthquake Disaster Mitigation 15, 16, 2001 | 12 | 2001 |
Predictive suboptimal semiactive control of earthquake response U Aldemir Structural Control and Health Monitoring 17 (6), 654-674, 2010 | 11 | 2010 |
Modified disturbance rejection problem U Aldemir Computers & structures 81 (15), 1547-1553, 2003 | 9 | 2003 |
Energy-based evaluation of seismic response of structures with passive and active systems A Yanik, U Aldemir, M Bakioglu Proc. of the Earthquake Resistant Engineering Structures VIII, 67-78, 2011 | 5 | 2011 |