关注
David Tilly
David Tilly
在 igp.uu.se 的电子邮件经过验证
标题
引用次数
引用次数
年份
Dose mapping sensitivity to deformable registration uncertainties in fractionated radiotherapy–applied to prostate proton treatments
D Tilly, N Tilly, A Ahnesjö
BMC medical physics 13, 1-12, 2013
312013
Fast dose algorithm for generation of dose coverage probability for robustness analysis of fractionated radiotherapy
D Tilly, A Ahnesjö
Physics in Medicine & Biology 60 (14), 5439, 2015
202015
Patient specific deep learning based segmentation for magnetic resonance guided prostate radiotherapy
S Fransson, D Tilly, R Strand
Physics and Imaging in Radiation Oncology 23, 38-42, 2022
182022
End-to-end validation of the geometric dose delivery performance of MR linac adaptive radiotherapy
U Bernchou, RL Christiansen, A Bertelsen, D Tilly, HL Riis, HR Jensen, ...
Physics in Medicine & Biology 66 (4), 045034, 2021
152021
Dose coverage calculation using a statistical shape model—applied to cervical cancer radiotherapy
D Tilly, AJAJ Van De Schoot, E Grusell, A Bel, A Ahnesjö
Physics in Medicine & Biology 62 (10), 4140, 2017
142017
Probabilistic optimization of dose coverage in radiotherapy
D Tilly, Å Holm, E Grusell, A Ahnesjö
Physics and Imaging in Radiation Oncology 10, 1-6, 2019
112019
Adaptive dose painting for prostate cancer
E Freden, D Tilly, A Ahnesjö
Frontiers in Oncology 12, 973067, 2022
52022
Computing radiotherapy dose distribution
M Eriksson, JO Sjölund, L Öström, DA Tilly, P Kimstrand, JA Adler
US Patent 11,020,615, 2021
52021
Intrafractional motion models based on principal components in Magnetic Resonance guided prostate radiotherapy
S Fransson, D Tilly, A Ahnesjö, T Nyholm, R Strand
Physics and Imaging in Radiation Oncology 20, 17-22, 2021
42021
The quality assurance of a 1.5 T MR-Linac
HL Riis, J Chick, A Dunlop, D Tilly
Seminars in radiation oncology 34 (1), 120-128, 2024
32024
Machine learning based dose guided real-time adaptive radiotherapy
DA Tilly, SL Riad, P Kimstrand, NT Tilly, KM von Würtemberg
US Patent App. 16/413,562, 2020
32020
Radiation attenuation comparison of the couch and coil structures for two Unity MR-Linacs
D Tilly, N Tilly, RL Christiansen, BC Buthler, TL Schierbeck, UU Bernchou, ...
Radiotherapy and Oncology 152 (Suppl. 1), S731-S732, 2020
22020
Probabilistic treatment planning based on dose coverage: how to quantify and minimize the effects of geometric uncertainties in radiotherapy
D Tilly
Acta Universitatis Upsaliensis, 2016
22016
Dosimetric validation of the couch and coil model for high-field MR-linac treatment planning
HL Riis, RL Christiansen, N Tilly, D Tilly
Zeitschrift für Medizinische Physik 33 (4), 567-577, 2023
12023
PO-1730 Logfile based automatic patient QA for daily MR guided adaptive radiotherapy
D Tilly, S Fransson, M Lundmark, U Isacsson, A Johansson
Radiotherapy and Oncology 182, S1448-S1449, 2023
12023
Dose guided real-time adaptive radiotherapy
DA Tilly, SL Riad, P Kimstrand, NT Tilly, KM von Würtemberg
US Patent 11,141,609, 2021
12021
Deep learning-based dose prediction for magnetic resonance-guided prostate radiotherapy
S Fransson, R Strand, D Tilly
2024
Deep learning segmentation of low-resolution images for prostate magnetic resonance-guided radiotherapy
S Fransson, D Tilly, R Strand
arXiv preprint arXiv:2310.11358, 2023
2023
PO-1898 Intra-fraction motion until, and during, beam on for MR guided adaptive prostate treatments
D Tilly, S Fransson, M Lundmark, U Isacsson, A Johansson, N Tilly, ...
Radiotherapy and Oncology 182, S1644-S1645, 2023
2023
PO-1691 Segmentation on low resolution magnetic resonance images for prostate radiotherapy
S Fransson, R Strand, D Tilly
Radiotherapy and Oncology 182, S1402-S1403, 2023
2023
系统目前无法执行此操作,请稍后再试。