Modeling of radio‐frequency induced currents on lead wires during MR imaging using a modified transmission line method V Acikel, E Atalar Medical Physics 38 (12), 6623-6632, 2011 | 69 | 2011 |
A temperature sensor implant for active implantable medical devices for in vivo subacute heating tests under MRI B Silemek, V Acikel, C Oto, A Alipour, ZG Aykut, O Algin, E Atalar Magnetic resonance in medicine 79 (5), 2824-2832, 2018 | 33 | 2018 |
Modeling of electrodes and implantable pulse generator cases for the analysis of implant tip heating under MR imaging V Acikel, A Uslubas, E Atalar Medical physics 42 (7), 3922-3931, 2015 | 28 | 2015 |
Wireless control of induced radiofrequency currents in active implantable medical devices during MRI V Acikel, B Silemek, E Atalar Magnetic resonance in medicine 83 (6), 2370-2381, 2020 | 11 | 2020 |
RF induced heating of pacemaker/ICD lead-tips during MRI Scans at 1.5 T and 3T: evaluation in cadavers DBE Volkan Acikel, Patrick Magrath, Scott E Parker, Peng Hu, Holden H Wu, J ... Journal of Cardiovascular Magnetic Resonance 18 (1), O121, 2016 | 9* | 2016 |
Digital feedback design for mutual coupling compensation in gradient array system R Babaloo, S Taraghinia, V Acikel, M Takrimi, E Atalar Proceedings of the 28th Annual Meeting of ISMRM, 2020 | 7 | 2020 |
A 12-channel degenerate birdcage body transmit array coil for 1.5 T MRI scanners E Kazemivalipour, A Sadeghi-Tarakameh, U Yilmaz, V Acikel, B Sen, ... Proceeding of the 26th Joint Annual Meeting ISMRM-ESMRMB, Paris, France. p 1708, 2018 | 7 | 2018 |
A novel MRI based electrical properties measurement technique V Acikel, O Ulutan, AC Ozen, B Akin, Y Eryaman, E Atalar Proc. Intl. Soc. Mag. Reson. Med 21, 2013 | 4 | 2013 |
Prototype Hardware of FPGA controlled multi-channel all-digital RF transmitter for parallel magnetic resonance imaging F Filci, A Dogan, G Cansiz, B Sen, V Acikel, E Atalar Proc. Intl. Soc. Mag. Reson. Med 25, 2017 | 3 | 2017 |
Intravascular magnetic resonance imaging (MRI) V Acikel, E Atalar Biomedical Imaging, 186-213, 2014 | 3 | 2014 |
Localizing the excitation to reduce scan time using nonlinear gradient fields E Kopanoglu, U Yilmaz, B Akin, V Acikel, E Atalar Proc. Intl. Soc. Mag. Reson. Med. 20, Melbourne, Australia, p3471, 2012 | 3 | 2012 |
Analysis of current induction on thin conductors inside the body during MRI scan V Açıkel PQDT-Global, 2014 | 2 | 2014 |
Decreasing SAR of a multi-dimensional central brightening inhomogeneity correction pulse using nonlinear gradient fields and VERSE E Kopanoglu, Y Gokhalk, U Yilmaz, V Acikel, E Atalar Proc. Intl. Soc. Mag. Reson. Med. 20, Melbourne, Australia, p3470, 2012 | 2 | 2012 |
Modeling of RF induced implant lead current for MRI V Acikel, E Atalar 17th Annu. Meet. ISMRM, Honolulu, HI, 2009 | 2 | 2009 |
Wireless MR-Compatibility Control of Active Implantable Medical Devices B Silemek, V Açıkel, U Yılmaz, E Atalar Proc. Intl. Soc. Mag. Reson. Med 26, 644, 0 | 2 | |
Design and implementation of high switching frequency gradient power amplifier using eGaN devices S Taraghinia, V Acikel, R Babaloo, E Atalar Proceedings of the 29th Annual Meeting of ISMRM, 2021 | 1 | 2021 |
RF Safety of Active Implantable Medical Devices B Silemek, V Açıkel, E Atalar Safety and Biological Effects in MRI, 311, 2020 | 1 | 2020 |
High resolution PWM generation for high frequency switching gradient amplifier control V Acikel, A Dogan, FE Filci, G Cansiz, E Atalar of the 27th Annual Meeting of ISMRM, 2019 | 1 | 2019 |
Temperature Sensor Implant for Analysis of RF Safety of Active Implantable Medical Devices under MRI B Silemek, V Acikel, E Atalar Proc. Intl. Soc. Mag. Reson. Med 23, 3218, 2015 | 1 | 2015 |
Effect of linear phase electric field variation on implant lead heating Y Eryaman, V Acikel, E Abaci Turk, NV Viskusenko, E Atalar Proceedings of the 18th Annual Meeting of ISMRM, Stocknolm, Sweden: Mira …, 2010 | 1 | 2010 |