Full-scale structural and nonstructural building system performance during earthquakes: Part I–specimen description, test protocol, and structural response MC Chen, E Pantoli, X Wang, R Astroza, H Ebrahimian, TC Hutchinson, ... Earthquake Spectra 32 (2), 737-770, 2016 | 118 | 2016 |
Review of fiber optic sensors for structural fire engineering Y Bao, Y Huang, MS Hoehler, G Chen Sensors 19 (4), 877, 2019 | 102 | 2019 |
Behavior and testing of fastenings to concrete for use in seismic applications MS Hoehler | 98 | 2006 |
Fire safety challenges of tall wood buildings-phase 2: task 3-cross laminated timber compartment fire tests J Su, PS Lafrance, M Hoehler, M Bundy Joseph Su, Pier-Simon Lafrance, Matthew Hoehler, Matthew Bundy, 2018 | 90 | 2018 |
Seismic performance of cold-formed steel wall systems in a full-scale building X Wang, E Pantoli, TC Hutchinson, JI Restrepo, RL Wood, MS Hoehler, ... Journal of Structural Engineering 141 (10), 04015014, 2015 | 80 | 2015 |
Full-scale structural and nonstructural building system performance during earthquakes: Part II–NCS damage states E Pantoli, MC Chen, X Wang, R Astroza, H Ebrahimian, TC Hutchinson, ... Earthquake Spectra 32 (2), 771-794, 2016 | 79 | 2016 |
Simple phenomenological model for reinforcing steel under arbitrary load MS Hoehler, JF Stanton Journal of Structural Engineering 132 (7), 1061-1069, 2006 | 66 | 2006 |
Behavior of steel-sheathed shear walls subjected to seismic and fire loads MS Hoehler, CM Smith, TC Hutchinson, X Wang, BJ Meacham, P Kamath Fire safety journal 91, 524-531, 2017 | 59 | 2017 |
Behavior and testing of anchors in simulated seismic cracks MS Hoehler, R Eligehausen ACI Structural Journal 105 (3), 348, 2008 | 59 | 2008 |
A novel application of silicone-based flame-retardant adhesive in plywood W Wang, M Zammarano, JR Shields, ED Knowlton, I Kim, JA Gales, ... Construction and Building Materials 189, 448-459, 2018 | 56 | 2018 |
Temperature measurement and damage detection in concrete beams exposed to fire using PPP-BOTDA based fiber optic sensors Y Bao, MS Hoehler, CM Smith, M Bundy, G Chen Smart materials and structures 26 (10), 105034, 2017 | 56 | 2017 |
Behavior of Anchors in Concrete at Seismic-Relevant Loading Rates. MS Hoehler, P Mahrenholtz, R Eligehausen ACI Structural Journal 108 (2), 2011 | 53 | 2011 |
Coherent laser ranging for precision imaging through flames EW Mitchell, MS Hoehler, FR Giorgetta, T Hayden, GB Rieker, ... Optica 5 (8), 988-995, 2018 | 52 | 2018 |
Performance of suspended pipes and their anchorages during shake table testing of a seven-story building MS Hoehler, M Panagiotou, JI Restrepo, JF Silva, L Floriani, U Bourgund, ... Earthquake Spectra 25 (1), 71-91, 2009 | 44 | 2009 |
Behavior of post-installed anchors tested by stepwise increasing cyclic load protocols P Mahrenholtz, R Eligehausen, TC Hutchinson, MS Hoehler ACI structural journal 113 (5), 997, 2016 | 42 | 2016 |
Survey and Characterization of Floor and Wall Mounted Mechanical and Electrical Equipment in Buildings DA Watkins, L Chiu, TC Hutchinson, MS Hoehler STRUCTURAL SYSTEMS RESEARCH PROJECT, UCSD, 2009 | 42 | 2009 |
Experimental analysis of steel beams subjected to fire enhanced by Brillouin scattering-based fiber optic sensor data Y Bao, Y Chen, MS Hoehler, CM Smith, M Bundy, G Chen Journal of Structural Engineering 143 (1), 04016143, 2017 | 37 | 2017 |
Testing anchors in cracked concrete R Eligehausen, L Mattis, R Wollmershauser, MS Hoehler Concrete international 26 (7), 66-71, 2004 | 36 | 2004 |
Use of catenary cables to prevent progressive collapse of buildings A Astaneh-Asl, EA Madsen, C Noble, R Jung, DB McCallen, MS Hoehler, ... Rep. No. UCB/CEE-Steel-2001 2, 2001 | 36 | 2001 |
Behavior and limit states of long-span composite floor beams with simple shear connections subject to compartment fires: experimental evaluation L Choe, S Ramesh, W Grosshandler, M Hoehler, M Seif, J Gross, ... Journal of Structural Engineering 146 (6), 04020088, 2020 | 31 | 2020 |