High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter SH Yun, C Boudoux, GJ Tearney, BE Bouma Optics letters 28 (20), 1981-1983, 2003 | 651 | 2003 |
Extended-cavity semiconductor wavelength-swept laser for biomedical imaging SH Yun, C Boudoux, MC Pierce, JF De Boer, GJ Tearney, BE Bouma Ieee Photonics Technology Letters 16 (1), 293-295, 2004 | 277 | 2004 |
Rapid wavelength-swept spectrally encoded confocal microscopy C Boudoux, SH Yun, WY Oh, WM White, NV Iftimia, M Shishkov, ... Optics Express 13 (20), 8214-8221, 2005 | 141 | 2005 |
Dual-modality needle probe for combined fluorescence imaging and three-dimensional optical coherence tomography D Lorenser, BC Quirk, M Auger, WJ Madore, RW Kirk, N Godbout, ... Optics letters 38 (3), 266-268, 2013 | 87 | 2013 |
Double-clad fiber coupler for endoscopy S Lemire-Renaud, M Rivard, M Strupler, D Morneau, F Verpillat, ... Optics express 18 (10), 9755-9764, 2010 | 87 | 2010 |
Fundamentals of Biomedical Optics C Boudoux Blurb, 2016 | 71 | 2016 |
Comprehensive imaging of gastroesophageal biopsy samples by spectrally encoded confocal microscopy DK Kang, MJ Suter, C Boudoux, H Yoo, PS Yachimski, WP Puricelli, ... Gastrointestinal endoscopy 71 (1), 35-43, 2010 | 63 | 2010 |
GRISM-based probe for spectrally encoded confocal microscopy C Pitris, BE Bouma, M Shishkov, C Boudoux, GJ Tearney European Conference on Biomedical Optics 2003, 139-146, 2003 | 63 | 2003 |
Large area confocal microscopy D Yelin, C Boudoux, BE Bouma, GJ Tearney Optics letters 32 (9), 1102-1104, 2007 | 60 | 2007 |
Molecular imaging needles: dual-modality optical coherence tomography and fluorescence imaging of labeled antibodies deep in tissue L Scolaro, D Lorenser, WJ Madore, RW Kirk, AS Kramer, GC Yeoh, ... Biomedical optics express 6 (5), 1767-1781, 2015 | 59 | 2015 |
Asymmetric double-clad fiber couplers for endoscopy WJ Madore, E De Montigny, O Ouellette, S Lemire-Renaud, M Leduc, ... Optics letters 38 (21), 4514-4517, 2013 | 46 | 2013 |
Simple and robust calibration procedure for k-linearization and dispersion compensation in optical coherence tomography X Attendu, RM Ruis, C Boudoux, TG Van Leeuwen, DJ Faber Journal of biomedical optics 24 (5), 056001-056001, 2019 | 45 | 2019 |
Endoscopic high-resolution autofluorescence imaging and OCT of pulmonary vascular networks H Pahlevaninezhad, AMD Lee, G Hohert, S Lam, T Shaipanich, ... Optics letters 41 (14), 3209-3212, 2016 | 45 | 2016 |
Endovascular procedures under near–real-time magnetic resonance imaging guidance: An experimental feasibility study YM Dion, HB El Kadi, C Boudoux, J Gourdon, N Chakfé, A Traoré, ... Journal of vascular surgery 32 (5), 1006-1014, 2000 | 44 | 2000 |
Multiplexed two-photon microscopy of dynamic biological samples with shaped broadband pulses RS Pillai, C Boudoux, G Labroille, N Olivier, I Veilleux, E Farge, M Joffre, ... Optics express 17 (15), 12741-12752, 2009 | 42 | 2009 |
Multimodality optical imaging of embryonic heart microstructure R Yelin, D Yelin, WY Oh, SH Yun, C Boudoux, BJ Vakoc, BE Bouma, ... Journal of biomedical optics 12 (6), 064021-064021-12, 2007 | 42 | 2007 |
Laser tissue coagulation and concurrent optical coherence tomography through a double-clad fiber coupler K Beaudette, HW Baac, WJ Madore, M Villiger, N Godbout, BE Bouma, ... Biomedical Optics Express 6 (4), 1293-1303, 2015 | 40 | 2015 |
Simultaneous multimodal ophthalmic imaging using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography JD Malone, MT El-Haddad, I Bozic, LA Tye, L Majeau, N Godbout, ... Biomedical optics express 8 (1), 193-206, 2016 | 30 | 2016 |
Optical microscopy of the pediatric vocal fold C Boudoux, SC Leuin, WY Oh, MJ Suter, AE Desjardins, BJ Vakoc, ... Archives of Otolaryngology–Head & Neck Surgery 135 (1), 53-64, 2009 | 29 | 2009 |
Double-clad fiber coupler for partially coherent detection E De Montigny, WJ Madore, O Ouellette, G Bernard, M Leduc, M Strupler, ... Optics express 23 (7), 9040-9051, 2015 | 28 | 2015 |