Dopamine and cAMP-regulated phosphoprotein 32 kDa controls both striatal long-term depression and long-term potentiation, opposing forms of synaptic plasticity P Calabresi, P Gubellini, D Centonze, B Picconi, G Bernardi, K Chergui, ... Journal of Neuroscience 20 (22), 8443-8451, 2000 | 438 | 2000 |
Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films F Palmisano, R Rizzi, D Centonze, PG Zambonin Biosensors and Bioelectronics 15 (9-10), 531-539, 2000 | 313 | 2000 |
Tissue plasminogen activator controls multiple forms of synaptic plasticity and memory P Calabresi, M Napolitano, D Centonze, GA Marfia, P Gubellini, MA Teule, ... European Journal of Neuroscience 12 (3), 1002-1012, 2000 | 208 | 2000 |
Correlation between permselectivity and chemical structure of overoxidized polypyrrole membranes used in electroproduced enzyme biosensors F Palmisano, C Malitesta, D Centonze, PG Zambonin Analytical chemistry 67 (13), 2207-2211, 1995 | 181 | 1995 |
An interference free amperometric biosensor for the detection of biogenic amines in food products D Carelli, D Centonze, C Palermo, M Quinto, T Rotunno Biosensors and Bioelectronics 23 (5), 640-647, 2007 | 155 | 2007 |
A disposable, reagentless, third-generation glucose biosensor based on overoxidized poly (pyrrole)/tetrathiafulvalene− tetracyanoquinodimethane composite F Palmisano, PG Zambonin, D Centonze, M Quinto Analytical chemistry 74 (23), 5913-5918, 2002 | 150 | 2002 |
Amperometric biosensors based on electrosynthesised polymeric films F Palmisano, PG Zambonin, D Centonze Fresenius' Journal of Analytical Chemistry 366, 586-601, 2000 | 131 | 2000 |
Interference-free glucose sensor based on glucose-oxidase immobilized in an overoxidized non-conducting polypyrrole film D Centonze, A Guerrieri, C Malitesta, F Palmisano, PG Zambonin Fresenius' journal of analytical chemistry 342, 729-733, 1992 | 124 | 1992 |
An interference-free biosensor based on glucose oxidase electrochemically immobilized in a non-conducting poly (pyrrole) film for continuous subcutaneous monitoring of glucose … F Palmisano, D Centonze, A Guerrieri, PG Zambonin Biosensors and Bioelectronics 8 (9-10), 393-399, 1993 | 122 | 1993 |
Determination of aflatoxins in cereal flours by solid-phase microextraction coupled with liquid chromatography and post-column photochemical derivatization-fluorescence detection M Quinto, G Spadaccino, C Palermo, D Centonze Journal of Chromatography A 1216 (49), 8636-8641, 2009 | 109 | 2009 |
Urine protein profile of IgA nephropathy patients may predict the response to ACE‐inhibitor therapy MT Rocchetti, M Centra, M Papale, G Bortone, C Palermo, D Centonze, ... Proteomics 8 (1), 206-216, 2008 | 100 | 2008 |
Validation according to European Commission Decision 2002/657/EC of a confirmatory method for aflatoxin M1 in milk based on immunoaffinity columns and high performance liquid … M Muscarella, SL Magro, C Palermo, D Centonze Analytica chimica acta 594 (2), 257-264, 2007 | 95 | 2007 |
Permeation of solutes through an electropolymerized ultrathin poly‐o‐phenylenediamine film used as an enzyme‐entrapping membrane D Centonze, C Malitesta, F Palmisano, PG Zambonin Electroanalysis 6 (5‐6), 423-429, 1994 | 80 | 1994 |
Electrode modification with a poly(NiII‐tetramethyldibenzotetraaza[14]annulene) film. Electrochemical behavior and redox catalysis in alkaline solutions. I TRI Cataldi, D Centonze, G Ricciardi Electroanalysis 7 (4), 312-318, 1995 | 76 | 1995 |
A multiresidual method based on ion-exchange chromatography with conductivity detection for the determination of biogenic amines in food and beverages C Palermo, M Muscarella, D Nardiello, M Iammarino, D Centonze Analytical and Bioanalytical Chemistry 405, 1015-1023, 2013 | 74 | 2013 |
An interference-free first generation alcohol biosensor based on a gold electrode modified by an overoxidised non-conducting polypyrrole film D Carelli, D Centonze, A De Giglio, M Quinto, PG Zambonin Analytica chimica acta 565 (1), 27-35, 2006 | 71 | 2006 |
An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: Determination of lactate in serum by flow injection … F Palmisano, D Centonze, PG Zambonin Biosensors and Bioelectronics 9 (7), 471-479, 1994 | 68 | 1994 |
Simultaneous determination of water-and fat-soluble vitamins, lycopene and beta-carotene in tomato samples and pharmaceutical formulations: Double injection single run by … MT Melfi, D Nardiello, N Cicco, V Candido, D Centonze Journal of Food Composition and Analysis 70, 9-17, 2018 | 58 | 2018 |
Development of a new analytical method for the determination of sulfites in fresh meats and shrimps by ion-exchange chromatography with conductivity detection M Iammarino, A Di Taranto, M Muscarella, D Nardiello, C Palermo, ... Analytica Chimica Acta 672 (1-2), 61-65, 2010 | 58 | 2010 |
Validation of a confirmatory analytical method for the determination of aflatoxins B1, B2, G1 and G2 in foods and feed materials by HPLC with on-line photochemical … M Muscarella, M Iammarino, D Nardiello, S Lo Magro, C Palermo, ... Food Additives and Contaminants 26 (10), 1402-1410, 2009 | 58 | 2009 |