A review of the performance of different ventilation and airflow distribution systems in buildings G Cao, H Awbi, R Yao, Y Fan, K Sirén, R Kosonen, JJ Zhang Building and Environment 73, 171-186, 2014 | 515 | 2014 |
Protected zone ventilation and reduced personal exposure to airborne cross‐infection G Cao, PV Nielsen, RL Jensen, P Heiselberg, L Liu, J Heikkinen Indoor air 25 (3), 307-319, 2015 | 86 | 2015 |
Modelling and experimental study of performance of the protected occupied zone ventilation G Cao, K Sirén, S Kilpeläinen Energy and Buildings 68, 515-531, 2014 | 63 | 2014 |
Do surgeons and surgical facilities disturb the clean air distribution close to a surgical patient in an orthopedic operating room with laminar airflow? G Cao, MCA Storås, A Aganovic, LI Stenstad, JG Skogås American journal of infection control 46 (10), 1115-1122, 2018 | 62 | 2018 |
Particle Image Velocimetry (PIV) application in the measurement of indoor air distribution by an active chilled beam G Cao, M Sivukari, J Kurnitski, M Ruponen, O Seppänen Building and Environment 45 (9), 1932-1940, 2010 | 57 | 2010 |
Impact of surgical lights on the velocity distribution and airborne contamination level in an operating room with laminar airflow system A Aganovic, G Cao, LI Stenstad, JG Skogås Building and Environment 126, 42-53, 2017 | 55 | 2017 |
Simulation of the heating performance of the Kang system in one Chinese detached house using biomass G Cao, J Jokisalo, G Feng, L Duanmu, M Vuolle, J Kurnitski Energy and Buildings 43 (1), 189-199, 2011 | 51 | 2011 |
Modelling and simulation of the near-wall velocity of a turbulent ceiling attached plane jet after its impingement with the corner G Cao, M Ruponen, R Paavilainen, J Kurnitski Building and Environment 46 (2), 489-500, 2011 | 48 | 2011 |
Laminar airflow and mixing ventilation: Which is better for operating room airflow distribution near an orthopedic surgical patient? G Cao, AM Nilssen, Z Cheng, LI Stenstad, A Radtke, JG Skogås American journal of infection control 47 (7), 737-743, 2019 | 47 | 2019 |
PIV measurement of the attached plane jet velocity field at a high turbulence intensity level in a room G Cao, M Sivukari, J Kurnitski, M Ruponen International Journal of Heat and Fluid Flow 31 (5), 897-908, 2010 | 38 | 2010 |
Identifying key design parameters of the integrated energy system for a residential Zero Emission Building in Norway N Nord, LH Qvistgaard, G Cao Renewable Energy 87, 1076-1087, 2016 | 34 | 2016 |
Experimental investigation of the velocity distribution of the attached plane jet after impingement with the corner in a high room G Cao, M Ruponen, J Kurnitski Energy and Buildings 42 (6), 935-944, 2010 | 34 | 2010 |
Experimental investigation and modelling of a buoyant attached plane jet in a room G Cao, J Kurnitski, M Ruponen, O Seppänen Applied thermal engineering 29 (14-15), 2790-2798, 2009 | 32 | 2009 |
Evaluation of airborne contaminant exposure in a single-bed isolation ward equipped with a protected occupied zone ventilation system A Aganovic, G Cao Indoor and Built Environment 28 (8), 1092-1103, 2019 | 30 | 2019 |
Experimental study of the effect of turbulence intensities on the maximum velocity decay of an attached plane jet G Cao, C Kandzia, D Müller, J Heikkinen, R Kosonen, M Ruponen Energy and Buildings 65, 127-136, 2013 | 30 | 2013 |
Characterizing the Dynamic Interactions and Exposure Implications of a Particle-Laden Cough Jet with Different Room Airflow Regimes Produced by Low and High Momentum Jets G Cao, S Liu, BE Boor, A Novoselac Aerosol and Air Quality Research 15 (5), 1955-1966, 2015 | 23 | 2015 |
Active chilled beam wall jet prediction by the free convection model G Cao, J Kurnitski, P Mustakallio, O Seppänen International Journal of Ventilation 7 (2), 169-178, 2008 | 21 | 2008 |
Plane-air-jet corner zone modelling in a room ventilated by an active chilled beam G Cao, J Kurnitski, M Ruponen, P Mustakallio, O Seppänen International Journal of Ventilation 7 (4), 287-297, 2009 | 19 | 2009 |
Energy cost models for air supported sports hall in cold climates considering energy efficiency N Nord, HM Mathisen, G Cao Renewable Energy 84, 56-64, 2015 | 17 | 2015 |
Dynamic interaction of a downward plane jet and a cough jet with respect to particle transmission: An analytical and experimental study G Cao, S Liu, BE Boor, A Novoselac Journal of occupational and environmental hygiene 14 (8), 618-631, 2017 | 16 | 2017 |