On the choice of outlet boundary conditions for patient-specific analysis of aortic flow using computational fluid dynamics S Pirola, Z Cheng, OA Jarral, DP O'Regan, JR Pepper, T Athanasiou, ... Journal of biomechanics 60, 15-21, 2017 | 162 | 2017 |
4D flow analysis of BAV-related fluid-dynamic alterations: evidences of wall shear stress alterations in absence of clinically-relevant aortic anatomical remodeling F Piatti, F Sturla, MM Bissell, S Pirola, M Lombardi, I Nesteruk, ... Frontiers in physiology 8, 441, 2017 | 71 | 2017 |
4-D flow MRI-based computational analysis of blood flow in patient-specific aortic dissection S Pirola, B Guo, C Menichini, S Saitta, W Fu, Z Dong, XY Xu IEEE Transactions on Biomedical Engineering 66 (12), 3411-3419, 2019 | 67 | 2019 |
The influence of inlet velocity profile on predicted flow in type B aortic dissection CH Armour, B Guo, S Pirola, S Saitta, Y Liu, Z Dong, XY Xu Biomechanics and modeling in mechanobiology 20, 481-490, 2021 | 57 | 2021 |
Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet S Pirola, OA Jarral, DP O'Regan, G Asimakopoulos, JR Anderson, ... APL bioengineering 2 (2), 2018 | 54 | 2018 |
Towards the improved quantification of in vivo abnormal wall shear stresses in BAV-affected patients from 4D-flow imaging: Benchmarking and application to real data F Piatti, S Pirola, M Bissell, I Nesteruk, F Sturla, A Della Corte, A Redaelli, ... Journal of biomechanics 50, 93-101, 2017 | 50 | 2017 |
Evaluation of 4D flow MRI-based non-invasive pressure assessment in aortic coarctations S Saitta, S Pirola, F Piatti, E Votta, F Lucherini, F Pluchinotta, M Carminati, ... Journal of biomechanics 94, 13-21, 2019 | 45 | 2019 |
High wall shear stress can predict wall degradation in ascending aortic aneurysms: an integrated biomechanics study MY Salmasi, S Pirola, S Sasidharan, SM Fisichella, A Redaelli, OA Jarral, ... Frontiers in bioengineering and biotechnology 9, 750656, 2021 | 44 | 2021 |
Analysis of turbulence effects in a patient-specific aorta with aortic valve stenosis EL Manchester, S Pirola, MY Salmasi, DP O’Regan, T Athanasiou, XY Xu Cardiovascular engineering and technology 12, 438-453, 2021 | 34 | 2021 |
High wall stress may predict the formation of stent-graft–induced new entries after thoracic endovascular aortic repair C Menichini, S Pirola, B Guo, W Fu, Z Dong, XY Xu Journal of Endovascular Therapy 25 (5), 571-577, 2018 | 29 | 2018 |
Evaluation and verification of patient-specific modelling of type B aortic dissection CH Armour, B Guo, S Saitta, S Pirola, Y Liu, Z Dong, XY Xu Computers in biology and medicine 140, 105053, 2022 | 24 | 2022 |
Phase-contrast magnetic resonance imaging and computational fluid dynamics assessment of thoracic aorta blood flow: a literature review OA Jarral, MKH Tan, MY Salmasi, S Pirola, JR Pepper, DP O’Regan, ... European Journal of Cardio-Thoracic Surgery 57 (3), 438-446, 2020 | 20 | 2020 |
Evaluation of computational methodologies for accurate prediction of wall shear stress and turbulence parameters in a patient-specific aorta EL Manchester, S Pirola, MY Salmasi, DP O’Regan, T Athanasiou, XY Xu Frontiers in Bioengineering and Biotechnology 10, 836611, 2022 | 16 | 2022 |
Qualitative and quantitative assessments of blood flow on tears in type B aortic dissection with different morphologies S Saitta, B Guo, S Pirola, C Menichini, D Guo, Y Shan, Z Dong, XY Xu, ... Frontiers in Bioengineering and Biotechnology 9, 742985, 2021 | 11 | 2021 |
Dissection level within aortic wall layers is associated with propagation of type B aortic dissection: a swine model study B Guo, Z Dong, S Pirola, Y Liu, C Menichini, XY Xu, D Guo, W Fu European Journal of Vascular and Endovascular Surgery 58 (3), 415-425, 2019 | 11 | 2019 |
Hemodynamic evaluation using four-dimensional flow magnetic resonance imaging for a patient with multichanneled aortic dissection B Guo, S Pirola, D Guo, Z Dong, XY Xu, W Fu Journal of Vascular Surgery Cases, Innovations and Techniques 4 (1), 67-71, 2018 | 10 | 2018 |
Geometry and flow in ascending aortic aneurysms are influenced by left ventricular outflow tract orientation: Detecting increased wall shear stress on the outer curve of … MY Salmasi, S Pirola, S Mahuttanatan, SM Fisichella, S Sengupta, ... The Journal of Thoracic and Cardiovascular Surgery 166 (1), 11-21. e1, 2023 | 9 | 2023 |
Data-driven generation of 4D velocity profiles in the aneurysmal ascending aorta S Saitta, L Maga, C Armour, E Votta, DP O’Regan, MY Salmasi, ... Computer Methods and Programs in Biomedicine 233, 107468, 2023 | 9 | 2023 |
Fluid-structure interaction within models of patient-specific arteries: computational simulations and experimental validations S Schoenborn, S Pirola, MA Woodruff, MC Allenby IEEE Reviews in Biomedical Engineering, 2022 | 8 | 2022 |
Effect of vessel tortuosity on stress concentration at the distal stent–vessel interface: Possible link with new entry formation through biomechanical simulation WT Tan, YM Liew, MJ Mohamed Mokhtarudin, S Pirola, WN Wan Ab Naim, ... Journal of Biomechanical Engineering 143 (8), 081005, 2021 | 7 | 2021 |