Detection, characterization and quantification of inorganic engineered nanomaterials: A review of techniques and methodological approaches for the analysis of complex samples F Laborda, E Bolea, G Cepriá, MT Gómez, MS Jiménez, ... Analytica chimica acta 904, 10-32, 2016 | 435 | 2016 |
Selective identification, characterization and determination of dissolved silver (I) and silver nanoparticles based on single particle detection by inductively coupled plasma … F Laborda, J Jiménez-Lamana, E Bolea, JR Castillo Journal of Analytical Atomic Spectrometry 26 (7), 1362-1371, 2011 | 432 | 2011 |
Critical considerations for the determination of nanoparticle number concentrations, size and number size distributions by single particle ICP-MS F Laborda, J Jiménez-Lamana, E Bolea, JR Castillo Journal of Analytical Atomic Spectrometry 28 (8), 1220-1232, 2013 | 297 | 2013 |
Electrochemical affinity biosensors for detection of mycotoxins: A review JC Vidal, L Bonel, A Ezquerra, S Hernández, JR Bertolín, C Cubel, ... Biosensors and Bioelectronics 49, 146-158, 2013 | 282 | 2013 |
An electrochemical competitive biosensor for ochratoxin A based on a DNA biotinylated aptamer L Bonel, JC Vidal, P Duato, JR Castillo Biosensors and Bioelectronics 26 (7), 3254-3259, 2011 | 243 | 2011 |
Recent advances in electropolymerized conducting polymers in amperometric biosensors JC Vidal, E Garcia-Ruiz, JR Castillo Microchimica Acta 143, 93-111, 2003 | 231 | 2003 |
In situ preparation of a cholesterol biosensor: entrapment of cholesterol oxidase in an overoxidized polypyrrole film electrodeposited in a flow system: determination of total … JC Vidal, E Garcı́a, JR Castillo Analytica Chimica Acta 385 (1-3), 213-222, 1999 | 211 | 1999 |
Electrochemical hydride generation as a sample-introduction technique in atomic spectrometry: fundamentals, interferences, and applications F Laborda, E Bolea, JR Castillo Analytical and bioanalytical chemistry 388, 743-751, 2007 | 149 | 2007 |
Direct determination of uric acid in serum by a fluorometric-enzymatic method based on uricase J Galbán, Y Andreu, MJ Almenara, S de Marcos, JR Castillo Talanta 54 (5), 847-854, 2001 | 147 | 2001 |
Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped with self-assembled monolayers JC Vidal, J Espuelas, E Garcia-Ruiz, JR Castillo Talanta 64 (3), 655-664, 2004 | 141 | 2004 |
Size characterization and quantification of silver nanoparticles by asymmetric flow field-flow fractionation coupled with inductively coupled plasma mass spectrometry E Bolea, J Jiménez-Lamana, F Laborda, JR Castillo Analytical and Bioanalytical Chemistry 401, 2723-2732, 2011 | 125 | 2011 |
Comparison of biosensors based on entrapment of cholesterol oxidase and cholesterol esterase in electropolymerized films of polypyrrole and diaminonaphthalene derivatives for … JC Vidal, E Garcia-Ruiz, J Espuelas, T Aramendia, JR Castillo Analytical and bioanalytical chemistry 377, 273-280, 2003 | 109 | 2003 |
Multielement characterization of metal-humic substances complexation by size exclusion chromatography, asymmetrical flow field-flow fractionation, ultrafiltration and … E Bolea, MP Gorriz, M Bouby, F Laborda, JR Castillo, H Geckeis Journal of Chromatography A 1129 (2), 236-246, 2006 | 105 | 2006 |
Semiquantitative simultaneous determination of metals in olive oil using direct emulsion nebulization JR Castillo, MS Jiménez, L Ebdon Journal of Analytical Atomic Spectrometry 14 (9), 1515-1518, 1999 | 103 | 1999 |
A comparative study of immobilization methods of a tyrosinase enzyme on electrodes and their application to the detection of dichlorvos organophosphorus insecticide JC Vidal, S Esteban, J Gil, JR Castillo Talanta 68 (3), 791-799, 2006 | 102 | 2006 |
Evaluation of number concentration quantification by single-particle inductively coupled plasma mass spectrometry: microsecond vs. millisecond dwell times I Abad-Álvaro, E Peña-Vázquez, E Bolea, P Bermejo-Barrera, JR Castillo, ... Analytical and bioanalytical chemistry 408 (19), 5089-5097, 2016 | 100 | 2016 |
A chronoamperometric sensor for hydrogen peroxide based on electron transfer between immobilized horseradish peroxidase on a glassy carbon electrode and a diffusing ferrocene … JC Vidal, MA Yague, JR Castillo Sensors and Actuators B: Chemical 21 (2), 135-141, 1994 | 100 | 1994 |
In situ preparation of overoxidized PPy/oPPD bilayer biosensors for the determination of glucose and cholesterol in serum JC Vidal, E Garcıa, JR Castillo Sensors and Actuators B: Chemical 57 (1-3), 219-226, 1999 | 97 | 1999 |
Electropolymerization of pyrrole and immobilization of glucose oxidase in a flow system: influence of the operating conditions on analytical performance JC Vidal, E Garcia, JR Castillo Biosensors and bioelectronics 13 (3-4), 371-382, 1998 | 96 | 1998 |
About detectability and limits of detection in single particle inductively coupled plasma mass spectrometry F Laborda, AC Gimenez-Ingalaturre, E Bolea, JR Castillo Spectrochimica Acta Part B: Atomic Spectroscopy 169, 105883, 2020 | 91 | 2020 |