Deconvolution of sinusoidal rapid EPR scans M Tseitlin, GA Rinard, RW Quine, SS Eaton, GR Eaton Journal of magnetic resonance 208 (2), 279-283, 2011 | 70 | 2011 |
Use of rapid-scan EPR to improve detection sensitivity for spin-trapped radicals DG Mitchell, GM Rosen, M Tseitlin, B Symmes, SS Eaton, GR Eaton Biophysical journal 105 (2), 338-342, 2013 | 68 | 2013 |
X-band rapid-scan EPR of samples with long electron spin relaxation times: a comparison of continuous wave, pulse and rapid-scan EPR DG Mitchell, M Tseitlin, RW Quine, V Meyer, ME Newton, A Schnegg, ... Molecular Physics 111 (18-19), 2664-2673, 2013 | 64 | 2013 |
Imaging thiol redox status in murine tumors in vivo with rapid-scan electron paramagnetic resonance B Epel, SV Sundramoorthy, M Krzykawska-Serda, MC Maggio, M Tseytlin, ... Journal of Magnetic Resonance 276, 31-36, 2017 | 57 | 2017 |
X-band rapid-scan EPR of nitroxyl radicals DG Mitchell, RW Quine, M Tseitlin, SS Eaton, GR Eaton Journal of Magnetic Resonance 214, 221-226, 2012 | 53 | 2012 |
Digital EPR with an arbitrary waveform generator and direct detection at the carrier frequency M Tseitlin, RW Quine, GA Rinard, SS Eaton, GR Eaton Journal of magnetic resonance 213 (1), 119-125, 2011 | 52 | 2011 |
Comparison of continuous wave, spin echo, and rapid scan EPR of irradiated fused quartz DG Mitchell, RW Quine, M Tseitlin, V Meyer, SS Eaton, GR Eaton Radiation measurements 46 (9), 993-996, 2011 | 51 | 2011 |
Exchange phenomena in the electron paramagnetic resonance spectra of the nitroxyl and trityl radicals: multifunctional spectroscopy and imaging of local chemical microenvironment VV Khramtsov, AA Bobko, M Tseytlin, B Driesschaert Analytical chemistry 89 (9), 4758-4771, 2017 | 50 | 2017 |
Rapid‐Scan Electron Paramagnetic Resonance SS Eaton, RW Quine, M Tseitlin, DG Mitchell, GA Rinard, GR Eaton Multifrequency electron paramagnetic resonance: Data and techniques, 3-67, 2014 | 50 | 2014 |
Electron spin relaxation and heterogeneity of the 1: 1 α, γ-bisdiphenylene-β-phenylallyl (BDPA)/benzene complex DG Mitchell, RW Quine, M Tseitlin, RT Weber, V Meyer, A Avery, SS Eaton, ... The Journal of Physical Chemistry B 115 (24), 7986-7990, 2011 | 47 | 2011 |
Comparison of maximum entropy and filtered back-projection methods to reconstruct rapid-scan EPR images M Tseitlin, A Dhami, SS Eaton, GR Eaton Journal of Magnetic Resonance 184 (1), 157-168, 2007 | 47 | 2007 |
A resonated coil driver for rapid scan EPR RW Quine, DG Mitchell, M Tseitlin, SS Eaton, GR Eaton Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering 41 (4 …, 2012 | 42 | 2012 |
Corrections for sinusoidal background and non-orthogonality of signal channels in sinusoidal rapid magnetic field scans M Tseitlin, DG Mitchell, SS Eaton, GR Eaton Journal of Magnetic Resonance 223, 80-84, 2012 | 42 | 2012 |
Imaging of nitroxides at 250 MHz using rapid-scan electron paramagnetic resonance JR Biller, M Tseitlin, RW Quine, GA Rinard, HA Weismiller, H Elajaili, ... Journal of Magnetic Resonance 242, 162-168, 2014 | 39 | 2014 |
Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude J Möser, K Lips, M Tseytlin, GR Eaton, SS Eaton, A Schnegg Journal of Magnetic Resonance 281, 17-25, 2017 | 37 | 2017 |
Combining absorption and dispersion signals to improve signal-to-noise for rapid-scan EPR imaging M Tseitlin, RW Quine, GA Rinard, SS Eaton, GR Eaton Journal of Magnetic Resonance 203 (2), 305-310, 2010 | 37 | 2010 |
Background removal procedure for rapid scan EPR M Tseitlin, T Czechowski, RW Quine, SS Eaton, GR Eaton Journal of Magnetic Resonance 196 (1), 48-53, 2009 | 37 | 2009 |
Rapid frequency scan EPR M Tseitlin, GA Rinard, RW Quine, SS Eaton, GR Eaton Journal of magnetic resonance 211 (2), 156-161, 2011 | 32 | 2011 |
Rapid-scan EPR of immobilized nitroxides Z Yu, RW Quine, GA Rinard, M Tseitlin, H Elajaili, V Kathirvelu, ... Journal of Magnetic Resonance 247, 67-71, 2014 | 29 | 2014 |
Reconstruction of the first-derivative EPR spectrum from multiple harmonics of the field-modulated continuous wave signal M Tseitlin, SS Eaton, GR Eaton Journal of Magnetic Resonance 209 (2), 277-281, 2011 | 29 | 2011 |