Total-body quantitative parametric imaging of early kinetics of 18F-FDG T Feng, Y Zhao, H Shi, H Li, X Zhang, G Wang, PM Price, RD Badawi, ... Journal of Nuclear Medicine 62 (5), 738-744, 2021 | 72 | 2021 |
Whole-body parametric imaging of 18F-FDG PET using uEXPLORER with reduced scanning time Y Wu, T Feng, Y Zhao, T Xu, F Fu, Z Huang, N Meng, H Li, F Shao, ... Journal of Nuclear Medicine 63 (4), 622-628, 2022 | 44 | 2022 |
Non-rigid dual respiratory and cardiac motion correction methods after, during, and before image reconstruction for 4D cardiac PET T Feng, J Wang, G Fung, B Tsui Physics in Medicine & Biology 61 (1), 151, 2015 | 44 | 2015 |
Self-gating: an adaptive center-of-mass approach for respiratory gating in PET T Feng, J Wang, Y Sun, W Zhu, Y Dong, H Li IEEE transactions on medical imaging 37 (5), 1140-1148, 2017 | 40 | 2017 |
Design of the NeuroEXPLORER, a next-generation ultra-high performance human brain PET imager R Carson, E Berg, R Badawi, S Cherry, J Du, T Feng, K Fontaine, ... Journal of Nuclear Medicine 62 (supplement 1), 1120-1120, 2021 | 32 | 2021 |
Simplified protocol for whole‐body Patlak parametric imaging with 18F‐FDG PET/CT: Feasibility and error analysis S Yao, T Feng, Y Zhao, R Wu, R Wang, S Wu, C Li, B Xu Medical physics 48 (5), 2160-2169, 2021 | 25 | 2021 |
Systems and methods for correcting mismatch induced by respiratory motion in positron emission tomography image reconstruction J Wang, T Feng, H Li US Patent 10,504,250, 2019 | 21 | 2019 |
Deep learning-based image reconstruction for TOF PET with DIRECT data partitioning format T Feng, S Yao, C Xi, Y Zhao, R Wang, S Wu, C Li, B Xu Physics in Medicine & Biology 66 (16), 165007, 2021 | 20 | 2021 |
Total‐body parametric imaging using the Patlak model: feasibility of reduced scan time Y Wu, T Feng, Y Shen, F Fu, N Meng, X Li, T Xu, T Sun, F Gu, Q Wu, ... Medical Physics 49 (7), 4529-4539, 2022 | 18 | 2022 |
Real-time data-driven rigid motion detection and correction for brain scan with listmode PET T Feng, D Yang, W Zhu, Y Dong, H Li 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room …, 2016 | 18 | 2016 |
Image‐derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney T Feng, BMW Tsui, X Li, M Vranesic, MA Lodge, NCM Gulaldi, Z Szabo Medical physics 42 (11), 6736-6744, 2015 | 17 | 2015 |
Dual respiratory and cardiac motion estimation in PET imaging: methods design and quantitative evaluation T Feng, J Wang, BMW Tsui Medical physics 45 (4), 1481-1490, 2018 | 15 | 2018 |
Non-rigid respiratory motion correction for 4D gated PET sinogram data T Feng, BMW Tsui 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS …, 2013 | 13 | 2013 |
Non-line-of-sight optical scattering communication based on solar-blind ultraviolet light T Feng, F Xiong, Q Ye, Z Pan, Z Dong, Z Fang Optical Transmission, Switching, and Subsystems V 6783, 1008-1014, 2007 | 12 | 2007 |
A novel data-driven cardiac gating signal extraction method for PET T Feng, J Wang, Y Dong, J Zhao, H Li IEEE Transactions on Medical Imaging 38 (2), 629-637, 2018 | 10 | 2018 |
Systems and methods for positron emission tomography image reconstruction J Wang, H Li, T Feng US Patent 10,690,782, 2020 | 9 | 2020 |
A papillary muscle guided motion estimation method for gated cardiac imaging J Wang, GSK Fung, T Feng, BMW Tsui Medical Imaging 2013: Physics of Medical Imaging 8668, 671-679, 2013 | 9 | 2013 |
Modeling of the Renal Kinetics of the AT1 Receptor Specific PET Radioligand [11C]KR31173 NCM Gulaldi, J Xia, T Feng, K Hong, WB Mathews, D Ruben, IR Kamel, ... BioMed research international 2013 (1), 835859, 2013 | 9 | 2013 |
Methods and systems for emission computed tomography image reconstruction T Feng, J Wang, H Li US Patent 10,360,724, 2019 | 8 | 2019 |
Systems and methods for pet image reconstruction J Wang, T Feng, H Li, W Zhu US Patent 10,282,871, 2019 | 7 | 2019 |