Experimental study of the behavior of a valveless impedance pump AI Hickerson, D Rinderknecht, M Gharib Experiments in fluids 38, 534-540, 2005 | 152 | 2005 |
A valveless micro impedance pump driven by electromagnetic actuation D Rinderknecht, AI Hickerson, M Gharib Journal of Micromechanics and Microengineering 15 (4), 861, 2005 | 106 | 2005 |
Creep and cycle life in polypyrrole actuators JD Madden, D Rinderknecht, PA Anquetil, IW Hunter Sensors and Actuators A: Physical 133 (1), 210-217, 2007 | 89 | 2007 |
Device and method for treating hydrocephalus M Gharib, D Rinderknecht, M Gharib US Patent 7,524,298, 2009 | 78 | 2009 |
Method for selectively anchoring large numbers of nanoscale structures E Sansom, D Rinderknecht, M Gharib US Patent 7,955,644, 2011 | 58 | 2011 |
Controlled partial embedding of carbon nanotubes within flexible transparent layers EB Sansom, D Rinderknecht, M Gharib Nanotechnology 19 (3), 035302, 2007 | 49 | 2007 |
Method applying hemodynamic forcing and klf2 to initiate the growth and development of cardiac valves M Gharib, D Rinderknecht, A Forouhar, J Vermot, SE Fraser US Patent App. 12/837,369, 2011 | 47 | 2011 |
Intrinsic frequency for a systems approach to haemodynamic waveform analysis with clinical applications NM Pahlevan, P Tavallali, DG Rinderknecht, D Petrasek, RV Matthews, ... Journal of The Royal Society Interface 11 (98), 20140617, 2014 | 45 | 2014 |
Noninvasive iphone measurement of left ventricular ejection fraction using intrinsic frequency methodology NM Pahlevan, DG Rinderknecht, P Tavallali, M Razavi, TT Tran, MW Fong, ... Critical care medicine 45 (7), 1115-1120, 2017 | 44 | 2017 |
Large strain actuation in polypyrrole actuators PA Anquetil, D Rinderknecht, NA Vandesteeg, JD Madden, IW Hunter Smart structures and materials 2004: Electroactive polymer actuators and …, 2004 | 31 | 2004 |
Fluidic pump for heat management M Gharib, D Rinderknecht, M Tasooji US Patent 7,398,818, 2008 | 28 | 2008 |
Portable electronic hemodynamic sensor systems N Pahlevan, D Rinderknecht, P Tavallali, M Gharib US Patent App. 14/601,170, 2015 | 26 | 2015 |
Method for selectively anchoring and exposing large numbers of nanoscale structures EB Sansom, D Rinderknecht, M Gharib US Patent 8,846,143, 2014 | 24 | 2014 |
On the convergence and accuracy of the cardiovascular intrinsic frequency method P Tavallali, TY Hou, DG Rinderknecht, NM Pahlevan Royal Society open science 2 (12), 150475, 2015 | 22 | 2015 |
Experimental investigation of the effect of non-Newtonian behavior of blood flow in the Fontan circulation AL Cheng, NM Pahlevan, DG Rinderknecht, JC Wood, M Gharib European Journal of Mechanics-B/Fluids 68, 184-192, 2018 | 21 | 2018 |
In-line actuator for electromagnetic operation M Gharib, D Rinderknecht, M Barbic US Patent 8,197,234, 2012 | 21 | 2012 |
Accuracy of a novel handheld wireless platform for detection of cardiac dysfunction in anthracycline-exposed survivors of childhood cancer SH Armenian, D Rinderknecht, K Au, L Lindenfeld, G Mills, A Siyahian, ... Clinical Cancer Research 24 (13), 3119-3125, 2018 | 20 | 2018 |
Resonant multilayered impedance pump D Rinderknecht, M Gharib, L Loumes, AS Forouhar, A Hickerson US Patent 8,092,365, 2012 | 16 | 2012 |
Intrinsic frequencies of carotid pressure waveforms predict heart failure events: the Framingham heart study LL Cooper, J Rong, NM Pahlevan, DG Rinderknecht, EJ Benjamin, ... Hypertension 77 (2), 338-346, 2021 | 15 | 2021 |
A wireless optical handheld device for carotid waveform measurement and its validation in a clinical study D Rinderknecht, JM De Balasy, NM Pahlevan Physiological measurement 41 (5), 055008, 2020 | 14 | 2020 |