Design rationale and preclinical evaluation of the HeartMate 3 left ventricular assist system for hemocompatibility K Bourque, C Cotter, C Dague, D Harjes, O Dur, J Duhamel, K Spink, ... ASAIO journal 62 (4), 375-383, 2016 | 195 | 2016 |
Aortic arch morphogenesis and flow modeling in the chick embryo Y Wang, O Dur, MJ Patrick, JP Tinney, K Tobita, BB Keller, K Pekkan Annals of biomedical engineering 37, 1069-1081, 2009 | 101 | 2009 |
Computer-aided patient-specific coronary artery graft design improvements using CFD coupled shape optimizer O Dur, ST Coskun, KO Coskun, D Frakes, LB Kara, K Pekkan Cardiovascular engineering and technology 2, 35-47, 2011 | 76 | 2011 |
Computer modeling for the prediction of thoracic aortic stent graft collapse S Pasta, JS Cho, O Dur, K Pekkan, DA Vorp Journal of vascular surgery 57 (5), 1353-1361, 2013 | 63 | 2013 |
Neonatal aortic arch hemodynamics and perfusion during cardiopulmonary bypass K Pekkan, O Dur, K Sundareswaran, K Kanter, M Fogel, A Yoganathan, ... | 55 | 2008 |
Critical transitions in early embryonic aortic arch patterning and hemodynamics WJ Kowalski, O Dur, Y Wang, MJ Patrick, JP Tinney, BB Keller, K Pekkan PloS one 8 (3), e60271, 2013 | 54 | 2013 |
Cellular-level near-wall unsteadiness of high-hematocrit erythrocyte flow using confocal μPIV MJ Patrick, CY Chen, DH Frakes, O Dur, K Pekkan Experiments in fluids 50, 887-904, 2011 | 47 | 2011 |
Right ventricular outflow tract reconstruction with bicuspid valved polytetrafluoroethylene conduit M Yoshida, PD Wearden, O Dur, K Pekkan, VO Morell The Annals of thoracic surgery 91 (4), 1235-1239, 2011 | 44 | 2011 |
Pump and method for mixed flow blood pumping SH Reichenbach, SG Briana, WV Hodges, E Lee, YR Woo, O Dur, ... US Patent 10,279,093, 2019 | 40 | 2019 |
Axial flow blood pump O Dur, K Bourque US Patent 10,780,207, 2020 | 39 | 2020 |
Pump and method for mixed flow blood pumping YR Woo, O Dur, SH Reichenbach US Patent 10,724,534, 2020 | 39 | 2020 |
Design rationale and performance evaluation of the wavelet health wristband: benchtop validation of a wrist-worn physiological signal recorder O Dur, C Rhoades, MS Ng, R Elsayed, R van Mourik, MD Majmudar JMIR mHealth and uHealth 6 (10), e11040, 2018 | 37 | 2018 |
Machine learning detection of obstructive hypertrophic cardiomyopathy using a wearable biosensor EM Green, R van Mourik, C Wolfus, SB Heitner, O Dur, MJ Semigran NPJ digital medicine 2 (1), 57, 2019 | 36 | 2019 |
Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios O Dur, M Lara, D Arnold, S Vandenberghe, BB Keller, C DeGroff, ... Artificial organs 33 (11), 967-976, 2009 | 33 | 2009 |
Artificial valved conduits for cardiac reconstructive procedures and methods for their production M Yoshida, CD Bernstein, O Dur, K Pekkan US Patent 9,585,746, 2017 | 32 | 2017 |
Pump and method for mixed flow blood pumping SH Reichenbach, SG Briana, WV Hodges, E Lee, YR Woo, O Dur, ... US Patent 9,533,082, 2017 | 32 | 2017 |
Computational hemodynamic optimization predicts dominant aortic arch selection is driven by embryonic outflow tract orientation in the chick embryo WJ Kowalski, NC Teslovich, O Dur, BB Keller, K Pekkan Biomechanics and modeling in mechanobiology 11, 1057-1073, 2012 | 27 | 2012 |
Optimization of inflow waveform phase-difference for minimized total cavopulmonary power loss O Dur, CG DeGroff, BB Keller, K Pekkan | 25 | 2010 |
Assessment of a standalone photoplethysmography (PPG) algorithm for detection of atrial fibrillation on wristband-derived data JL Selder, T Proesmans, L Breukel, O Dur, W Gielen, AC van Rossum, ... Computer Methods and Programs in Biomedicine 197, 105753, 2020 | 24 | 2020 |
Design and Principle of Operation of the HeartMate PHPTM(Percutaneous NM Van Mieghem, J Daemen, C Den Uil, O Dur, L Joziasse, A Maugenest, ... Age 74, 9, 2018 | 24 | 2018 |