关注
Davood Ghadiri Moghaddam
Davood Ghadiri Moghaddam
PhD, P.Eng
在 nimbus.cool 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
A parametric study of cathode catalyst layer structural parameters on the performance of a PEM fuel cell
N Khajeh-Hosseini-Dalasm, MJ Kermani, DG Moghaddam, JM Stockie
International journal of hydrogen energy 35 (6), 2417-2427, 2010
1822010
Comparison of experimental data and a model for heat and mass transfer performance of a liquid-to-air membrane energy exchanger (LAMEE) when used for air dehumidification and …
G Ge, DG Moghaddam, AH Abdel-Salam, RW Besant, CJ Simonson
International Journal of Heat and Mass Transfer 68, 119-131, 2014
1002014
Numerical model of a small-scale liquid-to-air membrane energy exchanger: Parametric study of membrane resistance and air side convective heat transfer coefficient
DG Moghaddam, A Oghabi, G Ge, RW Besant, CJ Simonson
Applied Thermal Engineering 61 (2), 245-258, 2013
822013
Analytical model based performance evaluation, sizing and coupling flow optimization of liquid desiccant run-around membrane energy exchanger systems
G Ge, DG Moghaddam, R Namvar, CJ Simonson, RW Besant
Energy and Buildings 62, 248-257, 2013
812013
Small-scale single-panel liquid-to-air membrane energy exchanger (LAMEE) test facility development, commissioning and evaluating the steady-state performance
DG Moghaddam, P LePoudre, G Ge, RW Besant, CJ Simonson
Energy and Buildings 66, 424-436, 2013
652013
Solution-side effectiveness for a liquid-to-air membrane energy exchanger used as a dehumidifier/regenerator
DG Moghaddam, RW Besant, CJ Simonson
Applied energy 113, 872-882, 2014
552014
Material properties and measurements for semi-permeable membranes used in energy exchangers
G Ge, GI Mahmood, DG Moghaddam, CJ Simonson, RW Besant, ...
Journal of membrane science 453, 328-336, 2014
472014
Steady-state performance of a small-scale liquid-to-air membrane energy exchanger for different heat and mass transfer directions, and liquid desiccant types and concentrations …
D Ghadiri Moghaddam, P LePoudre, RW Besant, CJ Simonson
Journal of heat transfer 135 (12), 122002, 2013
31*2013
Systems and methods for providing cooling to a heat load
PP LePoudre, M Gerber, DG Moghaddam
US Patent 11,092,349, 2021
252021
Three-fluid liquid to air membrane energy exchanger
PP LePoudre, DG Moghaddam, M Gerber
US Patent 10,962,252, 2021
202021
Systems and methods for providing cooling to a heat load
PP LePoudre, M Gerber, DG Moghaddam
US Patent 10,808,951, 2020
192020
Systems and methods for managing conditions in enclosed space
DG Moghaddam, PP LePoudre, M Gerber
US Patent 10,197,310, 2019
152019
A methodology for scaling a small-scale energy exchanger performance results to a full-scale energy exchanger
DG Moghaddam, RW Besant, CJ Simonson
International Journal of Heat and Mass Transfer 82, 555-567, 2015
122015
Investigating similarity between a small-scale liquid-to-air membrane energy exchanger (LAMEE) and a full-scale (100 L/s) LAMEE: Experimental and numerical results
DG Moghaddam, M Fauchoux, RW Besant, CJ Simonson
International Journal of Heat and Mass Transfer 77, 464-474, 2014
122014
Steady-state performance of a prototype (200 CFM) liquid-to-air membrane energy exchanger (LAMEE) under summer and winter test conditions
D Ghadiri Moghaddam, G Mahmood, G Ge, J Bolster, RW Besant, ...
Heat Transfer Summer Conference 55478, V001T01A014, 2013
122013
Evaluating the steady-state performance of a small-scale single-panel liquid-to-air membrane energy exchanger (LAMEE) under summer AHRI test condition
DG Moghaddam, P LePoudre, RW Besant, CJ Simonson
Proceedings, 2013
122013
Effectiveness evaluation of a liquid-to-air membrane energy exchangers as dehumidifier/regenerator in a liquid desiccant air-conditioning system
AH Abdel-Salam, G Ge, MT Fauchoux, DG Moghaddam, CJ Simonson
Proceedings of the 24th CANCAM, Saskatoon, Saskatchewan, Canada, 2013
72013
Using liquid to air membrane energy exchanger for liquid cooling
DG Moghaddam, PP LePoudre, M Gerber
US Patent 11,143,430, 2021
52021
Effects of solution inlet temperature on the effectiveness and moisture removal rate of a liquid-to-air membrane energy exchanger (LAMEE) during regenerator operating conditions
DG Moghaddam, G Ge, AH Abdel-Salam, RW Besant, CJ Simonson
Proc. In: Proceedings of the 24th CANCAM, 2013
52013
Analytical model based performance evaluation and optimization of run-around membrane energy exchanger systems
G Ge, D Ghadiri Moghaddam, R Namvar, RW Besant, CJ Simonson
Energy Build 62, 248-257, 2012
52012
系统目前无法执行此操作,请稍后再试。
文章 1–20