AC-coupled front-end for biopotential measurements EM Spinelli, R Pallàs-Areny, MA Mayosky IEEE transactions on biomedical engineering 50 (3), 391-395, 2003 | 311 | 2003 |
Insulating electrodes: a review on biopotential front ends for dielectric skin–electrode interfaces E Spinelli, M Haberman Physiological measurement 31 (10), S183, 2010 | 146 | 2010 |
A novel fully differential biopotential amplifier with DC suppression EM Spinelli, N Martínez, MA Mayosky, R Pallàs-Areny IEEE transactions on biomedical engineering 51 (8), 1444-1448, 2004 | 103 | 2004 |
A transconductance driven-right-leg circuit EM Spinelli, NH Martinez, MA Mayosky IEEE transactions on biomedical engineering 46 (12), 1466-1470, 1999 | 91 | 1999 |
Two-electrode biopotential measurements: power line interference analysis EM Spinelli, MA Mayosky IEEE Transactions on biomedical engineering 52 (8), 1436-1442, 2005 | 73 | 2005 |
A capacitive electrode with fast recovery feature E Spinelli, M Haberman, P García, F Guerrero Physiological measurement 33 (8), 1277, 2012 | 65 | 2012 |
A practical approach to electrode-skin impedance unbalance measurement EM Spinelli, MÁ Mayosky, R Pallás-Areny IEEE transactions on biomedical engineering 53 (7), 1451-1453, 2006 | 55 | 2006 |
A single supply biopotential amplifier EM Spinelli, NH Martinez, MA Mayosky Medical engineering & physics 23 (3), 235-238, 2001 | 50 | 2001 |
Smart wheelchairs and brain-computer interfaces: mobile assistive technologies P Diez Academic Press, 2018 | 45 | 2018 |
A multichannel EEG acquisition scheme based on single ended amplifiers and digital DRL MA Haberman, EM Spinelli IEEE Transactions on Biomedical Circuits and Systems 6 (6), 614-618, 2012 | 45 | 2012 |
A two-wired ultra-high input impedance active electrode FN Guerrero, EM Spinelli IEEE transactions on biomedical circuits and systems 12 (2), 437-445, 2018 | 43 | 2018 |
AC coupled three op-amp biopotential amplifier with active DC suppression EM Spinelli, MA Mayosky IEEE transactions on biomedical engineering 47 (12), 1616-1619, 2000 | 39 | 2000 |
A noncontact voltage measurement system for power-line voltage waveforms MA Haberman, EM Spinelli IEEE Transactions on Instrumentation and Measurement 69 (6), 2790-2797, 2019 | 37 | 2019 |
Nanoclusters of crystallographically aligned nanoparticles for magnetic thermotherapy: aqueous ferrofluid, agarose phantoms and ex vivo melanoma tumour assessment DF Coral, PA Soto, V Blank, A Veiga, E Spinelli, S Gonzalez, GP Saracco, ... Nanoscale 10 (45), 21262-21274, 2018 | 37 | 2018 |
Fully differential AC-coupling networks: a comparative study O Casas, EM Spinelli, R Pallas-Areny IEEE Transactions on Instrumentation and Measurement 58 (1), 94-98, 2008 | 37 | 2008 |
The assessment of a smart anticorrosive coating by the electrochemical noise technique MC Deyá, B Del Amo, E Spinelli, R Romagnoli Progress in Organic Coatings 76 (4), 525-532, 2013 | 36 | 2013 |
Analysis and simple circuit design of double differential EMG active electrode FN Guerrero, EM Spinelli, MA Haberman IEEE transactions on biomedical circuits and systems 10 (3), 787-795, 2015 | 35 | 2015 |
Surface EMG multichannel measurements using active, dry branched electrodes FN Guerrero, E Spinelli VI Latin American Congress on Biomedical Engineering CLAIB 2014, Paraná …, 2015 | 25 | 2015 |
Noncontact AC voltage measurements: Error and noise analysis MA Haberman, EM Spinelli IEEE Transactions on Instrumentation and Measurement 67 (8), 1946-1953, 2018 | 22 | 2018 |
A simple and reproducible capacitive electrode E Spinelli, F Guerrero, P García, M Haberman Medical Engineering & Physics 38 (3), 286-289, 2016 | 22 | 2016 |