Computational simulation of platelet deposition and activation: I. Model development and properties EN Sorensen, GW Burgreen, WR Wagner, JF Antaki Annals of biomedical engineering 27, 436-448, 1999 | 287 | 1999 |
Effects of turbulent stresses upon mechanical hemolysis: experimental and computational analysis MV Kameneva, GW Burgreen, K Kono, B Repko, JF Antaki, M Umezu ASAIO journal 50 (5), 418-423, 2004 | 238 | 2004 |
Assessment of CFD performance in simulations of an idealized medical device: results of FDA’s first computational interlaboratory study SFC Stewart, EG Paterson, GW Burgreen, P Hariharan, M Giarra, ... Cardiovascular Engineering and Technology 3, 139-160, 2012 | 208 | 2012 |
Computational fluid dynamics as a development tool for rotary blood pumps GW Burgreen, JF Antaki, ZJ Wu, AJ Holmes Artificial organs 25 (5), 336-340, 2001 | 192 | 2001 |
Computational simulation of platelet deposition and activation: II. Results for Poiseuille flow over collagen EN Sorensen, GW Burgreen, WR Wagner, JF Antaki Annals of biomedical engineering 27, 449-458, 1999 | 156 | 1999 |
Multilaboratory particle image velocimetry analysis of the FDA benchmark nozzle model to support validation of computational fluid dynamics simulations P Hariharan, M Giarra, V Reddy, SW Day, KB Manning, S Deutsch, ... | 151 | 2011 |
Three-dimensional aerodynamic shape optimization using discrete sensitivity analysis GW Burgreen, O Baysal AIAA journal 34 (9), 1761-1770, 1996 | 136 | 1996 |
Computational flow optimization of rotary blood pump components JF Antaki, O Ghattas, GW Burgreen, B He Artificial Organs 19 (7), 608-615, 1995 | 78 | 1995 |
Results of FDA’s first interlaboratory computational study of a nozzle with a sudden contraction and conical diffuser SFC Stewart, P Hariharan, EG Paterson, GW Burgreen, V Reddy, SW Day, ... Cardiovascular Engineering and Technology 4, 374-391, 2013 | 71 | 2013 |
Method and apparatus for providing limited back-flow in a blood pump during a non-pumping state M Heilman, C Capone, S Kolenik, D Moore, C Parisi, E Prem, R Sofranko, ... US Patent App. 10/325,275, 2003 | 66 | 2003 |
Aerodynamic shape optimization using preconditioned conjugate gradient methods GW Burgreen, O Baysal AIAA journal 32 (11), 2145-2152, 1994 | 65 | 1994 |
Three-dimensional aerodynamic shape optimization of wings using sensitivity analysis G Burgreen, O Baysal 32nd aerospace sciences meeting and exhibit, 94, 1994 | 65 | 1994 |
Predicting membrane oxygenator pressure drop using computational fluid dynamics KL Gage, MJ Gartner, GW Burgreen, WR Wagner Artificial Organs 26 (7), 600-607, 2002 | 63 | 2002 |
Touch down of blood pump impellers CD Capone, RC Dempsey, MS Heilman, SA Kolenik, DR Moore, ... US Patent 6,761,532, 2004 | 51 | 2004 |
Fluid dynamic characterization of operating conditions for continuous flow blood pumps ZJ Wu, JF Antaki, GW Burgreen, KC Butler, DC Thomas, BP Griffith Asaio Journal 45 (5), 442-449, 1999 | 51 | 1999 |
Improving the efficiency of aerodynamic shape optimization GW Burgreen, O Baysal, ME Eleshaky AIAA journal 32 (1), 69-76, 1994 | 49 | 1994 |
In vitro and in vivo evaluation of a novel integrated wearable artificial lung SP Madhani, BJ Frankowski, GW Burgreen, JF Antaki, R Kormos, ... The Journal of Heart and Lung Transplantation 36 (7), 806-811, 2017 | 45 | 2017 |
Computational fluid dynamics analysis of a maglev centrifugal left ventricular assist device GW Burgreen, HM Loree, K Bourque, C Dague, VL Poirier, D Farrar, ... Artificial organs 28 (10), 874-880, 2004 | 42 | 2004 |
Development progress of the University of Pittsburgh Streamliner: a mixed flow blood pump with magnetic bearings JF Antaki, GW Burgreen, ZJ Wu, D Borzelleca, MV Kameneva, JA Holmes, ... ASAIO Journal 46 (2), 194, 2000 | 41 | 2000 |
A design improvement strategy for axial blood pumps using computational fluid dynamics GW Burgreen, JF Antaki, BP Griffith Asaio Journal 42 (5), M354-359, 1996 | 41 | 1996 |