Comparing cone-beam CT intensity correction methods for dose recalculation in adaptive intensity-modulated photon and proton therapy for head and neck cancer C Kurz, G Dedes, A Resch, M Reiner, U Ganswindt, R Nijhuis, C Thieke, ... Acta oncologica 54 (9), 1651-1657, 2015 | 115 | 2015 |
Evaluation of electromagnetic and nuclear scattering models in GATE/Geant4 for proton therapy AF Resch, A Elia, H Fuchs, A Carlino, H Palmans, M Stock, D Georg, ... Medical Physics 46 (5), 2444-2456, 2019 | 48 | 2019 |
Quantification of the uncertainties of a biological model and their impact on variable RBE proton treatment plan optimization AF Resch, G Landry, F Kamp, G Cabal, C Belka, JJ Wilkens, K Parodi, ... Physica Medica 36, 91-102, 2017 | 42 | 2017 |
Monte Carlo proton dose calculations using a radiotherapy specific dual-energy CT scanner for tissue segmentation and range assessment IP Almeida, LEJR Schyns, A Vaniqui, B Van der Heyden, G Dedes, ... Physics in Medicine & Biology 63 (11), 115008, 2018 | 37 | 2018 |
Evaluation of GATE‐RTion (GATE/Geant4) Monte Carlo simulation settings for proton pencil beam scanning quality assurance C Winterhalter, M Taylor, D Boersma, A Elia, S Guatelli, R Mackay, ... Medical physics 47 (11), 5817-5828, 2020 | 32 | 2020 |
Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields F Padilla‐Cabal, J Alejandro Fragoso, A Franz Resch, D Georg, H Fuchs Medical physics 47 (1), 223-233, 2020 | 27 | 2020 |
A GATE/Geant4 beam model for the MedAustron non-isocentric proton treatment plans quality assurance A Elia, AF Resch, A Carlino, TT Böhlen, H Fuchs, H Palmans, V Letellier, ... Physica Medica 71, 115-123, 2020 | 26 | 2020 |
A Monte-Carlo study to assess the effect of 1.5 T magnetic fields on the overall robustness of pencil-beam scanning proton radiotherapy plans for prostate cancer C Kurz, G Landry, AF Resch, G Dedes, F Kamp, U Ganswindt, C Belka, ... Physics in Medicine & Biology 62 (21), 8470, 2017 | 25 | 2017 |
Computer‐assisted beam modeling for particle therapy H Fuchs, A Elia, AF Resch, P Kuess, A Lühr, M Vidal, L Grevillot, D Georg Medical Physics 48 (2), 841-851, 2021 | 17 | 2021 |
Implementation of a dose calculation algorithm based on Monte Carlo simulations for treatment planning towards MRI guided ion beam therapy F Padilla-Cabal, AF Resch, D Georg, H Fuchs Physica Medica 74, 155-165, 2020 | 17 | 2020 |
Dose‐rather than fluence‐averaged LET should be used as a single‐parameter descriptor of proton beam quality for radiochromic film dosimetry AF Resch, PD Heyes, H Fuchs, N Bassler, D Georg, H Palmans Medical Physics 47 (5), 2289-2299, 2020 | 17 | 2020 |
Investigation of the Bragg peak degradation caused by homogeneous and heterogeneous lung tissue substitutes: proton beam experiments and comparison to current clinical dose … A Hranek, AF Resch, D Georg, B Knäusl Physics in Medicine & Biology 65 (24), 245036, 2020 | 10 | 2020 |
Benchmarking GATE/Geant4 for 16O ion beam therapy AF Resch, H Fuchs, D Georg Physics in Medicine & Biology 62 (18), N474, 2017 | 8 | 2017 |
in silico benchmarking of the linear energy transfer‐based functionalities for carbon ion beams in a commercial treatment planning system M Schafasand, AF Resch, E Traneus, L Glimelius, P Fossati, M Stock, ... Medical Physics 50 (3), 1871-1878, 2023 | 7 | 2023 |
Investigation on the physical dose filtered by linear energy transfer for treatment plan evaluation in carbon ion therapy M Schafasand, AF Resch, A Nachankar, J Gora, E Traneus, L Glimelius, ... Medical Physics 51 (1), 556-565, 2024 | 5 | 2024 |
Experimental determination of the effective point of measurement of the PTW‐31010 ionization chamber in proton and carbon ion beams S Barna, AF Resch, M Puchalska, D Georg, H Palmans Medical Physics 49 (1), 675-681, 2022 | 5 | 2022 |
3D printed 2D range modulators preserve radiation quality on a microdosimetric scale in proton and carbon ion beams S Barna, C Meouchi, AF Resch, G Magrin, D Georg, H Palmans Radiotherapy and Oncology 182, 109525, 2023 | 4 | 2023 |
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams AF Resch, F Padilla Cabal, M Regodic, W Lechner, G Heilemann, ... Medical Physics 49 (9), 6150-6160, 2022 | 4 | 2022 |
Impact of beamline‐specific particle energy spectra on clinical plans in carbon ion beam therapy AF Resch, M Schafasand, N Lackner, T Niessen, S Beck, A Elia, ... Medical Physics 49 (6), 4092-4098, 2022 | 3 | 2022 |
Dose averaged linear energy transfer optimization for large sacral chordomas in carbon ion therapy M Schafasand, AF Resch, A Nachankar, J Góra, G Martino, E Traneus, ... Medical Physics 51 (6), 3950-3960, 2024 | 2 | 2024 |