Recommendations for the prevention, mitigation and containment of the emerging SARS-CoV-2 (COVID-19) pandemic in haemodialysis centres C Basile, C Combe, F Pizzarelli, A Covic, A Davenport, M Kanbay, ... Nephrology Dialysis Transplantation 35 (5), 737-741, 2020 | 380 | 2020 |
Overestimation of hemodialysis dose depends on dialysis efficiency by regional blood flow but not by conventional two pool urea kinetic analysis JT Daugirdas, D Schneditz ASAIO journal 41 (3), M719-M724, 1995 | 336 | 1995 |
Cardiopulmonary recirculation during hemodialysis D Schneditz, AM Kaufman, HD Polaschegg, NW Levin, JT Daugirdas Kidney international 42 (6), 1450-1456, 1992 | 206 | 1992 |
Nature and rate of vascular refilling during hemodialysis and ultrafiltration D Schneditz, J Roob, M Oswald, H Pogglitsch, M Moser, T Kenner, ... Kidney international 42 (6), 1425-1433, 1992 | 193 | 1992 |
Cardiovascular and respiratory systems: modeling, analysis, and control JJ Batzel, F Kappel, D Schneditz, HT Tran Society for Industrial and Applied Mathematics, 2007 | 183 | 2007 |
Characteristics of hypotension‐prone haemodialysis patients: is there a critical relative blood volume? C Barth, W Boer, D Garzoni, T Kuenzi, W Ries, R Schaefer, D Schneditz, ... Nephrology Dialysis Transplantation 18 (7), 1353-1360, 2003 | 181 | 2003 |
In vivo quantification of liver dialysis: comparison of albumin dialysis and fractionated plasma separation P Krisper, B Haditsch, R Stauber, A Jung, V Stadlbauer, M Trauner, ... Journal of hepatology 43 (3), 451-457, 2005 | 176 | 2005 |
Increasing access to integrated ESKD care as part of universal health coverage DCH Harris, SJ Davies, FO Finkelstein, V Jha, JA Donner, G Abraham, ... Kidney international 95 (4), S1-S33, 2019 | 172 | 2019 |
Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis F Zhu, D Schneditz, E Wang, NW Levin Journal of applied physiology 85 (2), 497-504, 1998 | 168 | 1998 |
A regional blood circulation alternative to in-series two compartment urea kinetic modeling D Schneditz, JC Van Stone, JT Daugirdas ASAIO journal 39 (3), M573-M577, 1993 | 165 | 1993 |
Compartment effects in hemodialysis D Schneditz, JT Daugirdas Seminars in dialysis 14 (4), 271-277, 2001 | 114 | 2001 |
A blood protein monitor for the continuous measurement of blood volume changes during hemodialysis D Schneditz, H Pogglitsch, J Horina, U Binswanger Kidney international 38 (2), 342-346, 1990 | 114 | 1990 |
Estimating phosphate removal in haemodialysis: an additional tool to quantify dialysis dose JP Gutzwiller, D Schneditz, AR Huber, C Schindler, F Gutzwiller, ... Nephrology Dialysis Transplantation 17 (6), 1037-1044, 2002 | 113 | 2002 |
Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique F Zhu, D Schneditz, E Wang, K Martin, AT Morris, NW Levin Asaio Journal 44 (5), M541-M545, 1998 | 113 | 1998 |
High-flux or low-flux dialysis: a position statement following publication of the Membrane Permeability Outcome study J Tattersall, B Canaud, O Heimburger, L Pedrini, D Schneditz, ... Nephrology Dialysis Transplantation 25 (4), 1230-1232, 2010 | 107 | 2010 |
Validation of haemodialysis recirculation and access blood flow measured by thermodilution. D Schneditz, E Wang, NW Levin Nephrology, dialysis, transplantation: official publication of the European …, 1999 | 106 | 1999 |
Means for determining hemodynamic parameters during extracorporeal blood treatment D Schneditz US Patent 5,830,365, 1998 | 103 | 1998 |
Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position F Zhu, D Schneditz, NW Levin Kidney international 56 (2), 692-699, 1999 | 95 | 1999 |
Evaluation of an ultrasonic blood volume monitor. C Johner, PW Chamney, D Schneditz, M Krämer Nephrology, Dialysis, Transplantation: Official Publication of the European …, 1998 | 94 | 1998 |
Isothermic hemodialysis and ultrafiltration LM Rosales, D Schneditz, AT Morris, S Rahmati, NW Levin American journal of kidney diseases 36 (2), 353-361, 2000 | 88 | 2000 |